– 50 –
Hydro Unit
Installation Manual
EN
Function code settings
Location & FC
Number
FC Description
Hydro
RC
Range
Default
After
Commissioning
Change
1
Change
2
1
Setting
Temperature
Range
Heating Upper Limit - Zone 1
1A
–
37~55 °C
55
Heating Lower Limit - Zone 1
1B
–
20~37 °C
20
Heating Upper Limit - Zone 2
1C
–
37~55 °C
55
Heating Lower Limit - Zone 2
1D
–
20~37 °C
20
Cooling - Upper Limit
18
–
18~30 °C
25
Cooling - Lower Limit
19
–
7~20 °C
7
Hot Water - Upper limit
1E
–
60~75 °C
75
Hot Water - Lower limit
1F
–
40~60 °C
40
2
Hot Water
Operation
Heat Pump Start Temperature
20
–
20~45 °C
38
Heat Pump Stop Temperature
21
–
40~50 °C
45
3
Hot Water
Temperature
Compensation
Temperature Compensation
Outside Air Temperature (°C)
24
–
-20~10 °C
0
Compensation Temperature
(°C)
25
–
0~15 °C
3
4
Hot Water Boost
Operation Time (x10 min)
08
–
3~18
6
Setting Temperature (°C)
09
–
40~75 °C
75
5
Anti Bacteria
Setting Temperature (°C)
0A
–
65~75 °C
75
Start Cycle (Day)
–
0D
1~10
7
Start Time (Hour)
–
0C
0~23
22
Operation Time (min)
0B
–
0~60
30
6
Priority Mode
Hot Water & Heating
Switching Temperature (°C)
22
–
-20~20
0
Boiler & Heat Pump Switching
Temperature (°C)
23
–
-20~20
-10
7
Heating Auto
Curve Settings
Outside Temperature T0 (°C)
A1
–
-30~-20 °C
-20
Outside Temperature T1 (°C)
29
–
-15~0 °C
-10
Outside Temperature T2 (°C)
–
–
0
0
Outside Temperature T3 (°C)
2B
–
0~15 °C
10
Setting Temperature A at T0
(°C) - ZONE 1
2C
–
20~55 °C
40
Setting Temperature B at T1
(°C) - ZONE 1
2D
–
20~55 °C
35
Setting Temperature C at T2
(°C) - ZONE 1
2E
–
20~55 °C
30
Setting Temperature D at T3
(°C) - ZONE 1
2F
–
20~55 °C
25
Setting Temperature E at
20 °C (°C) - ZONE 1
30
–
20~55 °C
20
ZONE2 temperature setting
0 = Percentage (FC 31)
1 = Fixed value (FCA3~A5)
A2
–
0~1
0
Ratio Of Zone 2 In Zone 1 Auto
Mode (%)
31
–
0~100%
80
Setting Temperature A’ at T0
(°C) - ZONE 2
A3
–
20~55 °C
40
Setting Temperature B’ at T1
(°C) - ZONE 2
A4
–
20~55 °C
35
Setting Temperature E’ at
20 °C (°C) - ZONE 2
A5
–
20~55 °C
20
Auto Curve - Temperature
Shift (°C)
27
–
-5~5 °C
0
50-EN
Summary of Contents for HWS-1405XWHM3-E