– 3 –
Hydro Unit
Installation Manual
Hydro Unit
4.5 kW model
8 kW model
11 kW, 14 kW, 16 kW model
Hot Water Cylinder (option)
Hydro Unit
HWS-455XWHM3-E
Back up heater capacity
(kW)
3.0
Power supply
for back up heater
220-230 V ~ 50 Hz
for hot water cylinder heater
(option)
220-230 V ~ 50 Hz
Leaving water
temperature
Heating
(°C)
20-55
Cooling
(°C)
7-25
Hydro Unit
HWS-805XWHM3-E
HWS-805XWHT6-E
HWS-805XWHT9-E
Back up heater capacity
(kW)
3.0
6.0
9.0
Power supply
for back up heater
220-230 V ~ 50 Hz
380-400 V 3N~ 50 Hz
380-400 V 3N~ 50 Hz
for hot water cylinder heater
(option)
220-230 V ~ 50 Hz
Leaving water
temperature
Heating
(°C)
20-55
Cooling
(°C)
7-25
Hydro Unit
HWS-1405XWHM3-E
HWS-1405XWHT6-E
HWS-1405XWHT9-E
Back up heater capacity
(kW)
3.0
6.0
9.0
Power supply
for back up heater
220-230 V ~ 50 Hz
380-400 V 3N~ 50 Hz
380-400 V 3N~ 50 Hz
for hot water cylinder heater
(option)
220-230 V ~ 50 Hz
Leaving water
temperature
Heating
(°C)
20-55
Cooling
(°C)
7-25
Hot water cylinder (option)
HWS-1501CSHM3-E
HWS-1501CSHM3-UK
HWS-2101CSHM3-E
HWS-2101CSHM3-UK
HWS-3001CSHM3-E
HWS-3001CSHM3-UK
Water volume
(liter)
150
210
300
Power supply
220-230 V ~ 50 Hz
Max water temperature
(°C)
75
Electric heater
(kW)
2.7
Height
(mm)
1,090
1,474
2,040
Diameter
(mm)
550
Material
Stainless steel
3-EN