No.
Condition
Analysis
Solution
Fuse F3201 disconnected
(Short circuit in LAN system)
Fuse F4201 disconnected
(Short circuit in system power supply)
Fuse F4301 disconnected
(Short circuit in 5V power supply system)
Fuse F4302 disconnected
(Short circuit in SDRAM power supply system)
Fuse F4303 disconnected
(Short circuit in HDD3.3V power supply system)
Fuse F4402 disconnected
(Short circuit in CCD-8V power supply system)
Fuse F4403 disconnected
(Short circuit in CCD13V power supply system)
Fuse F4401 disconnected
(Short circuit in U3V power supply system)
Fuse F4502 disconnected
(Short circuit in U3V power supply system)
Fuse F4501 disconnected
(Short circuit in battery charge system)
Fuse F4601 disconnected
(Short circuit in battery system)
Fuse F4701 disconnected
(Short circuit in system 3.3V)
Fuse F4802 disconnected
(Short circuit in motor system 5V)
Fuse F4801 disconnected
(Short circuit in 1.2V, 1.5V system)
Fuse F4902 disconnected
(Short circuit in CCD3.5V system)
Fuse F4901 disconnected
(Short circuit in LCD back light system)
Fuse F7001 disconnected
(Short circuit in cradle 10V system)
Fuse F6501 disconnected
(Short circuit in JACK board 10V system)
2
Not operational by
battery
MAIN board defect
Replace MAIN PCB ASSY (U001)
MAIN board defect
Replace MAIN PCB ASSY (U001)
Cradle defect
Replace cradle (Y540)
Wiring defect in hinge
Replace LCD (HA54)
MAIN board defect
Replace MAIN PCB ASSY (U001)
FPC-HEAD defect
CCD defect
AD converter defect
CCD board defect
Lens defect (iris)
MAIN board defect
Replace MAIN PCB ASSY (U001)
Wiring defect in hinge
Replace LCD ASSY (HA54)
MAIN board defect
Replace MAIN PCB ASSY (U001)
Lens defect
Replace Lens Module ASSY
Perform AE readjustment
Replace MAIN PCB ASSY (U001)
FPC-ZOOM defect
Replace Zoom Cover ASSY
(AA05)
MAIN board defect
Replace MAIN PCB ASSY (U001)
4. Troubleshooting
5
No image displayed
under the photography
mode
Replace Lens Module ASSY
(HA52)
1
The power does not
turn on.
Replace MAIN PCB ASSY (U001)
Replace Cradle (YR01)
Replace JACK PCB ASSY (UA02)
7
Screen is too
bright/dark under the
photography mode
Lens adjustment data defect
Unable to zoom
8
4
No image displayed on
the LCD monitor
6
LCD back light does
not turn on.
3
Not operational by AC
adapter
25
Summary of Contents for Gigashot GSC-R30
Page 12: ...2 Mechanical Parts 2 1 Explode Diagram GSC R60 11 ...
Page 13: ...GSC R30 12 ...
Page 58: ...GSC R60 GSC R30 ...