(2)-3. Sensor, Current, Compressor operation frequency, PMV openness indication
The values detected by controller, such as temperature sensor or current values, can be easily checked.
* TD, TL, and TH show errors below the ordinary temperature because they are sensors for high temperature.
* Current value for the outdoor unit only is shown.
Item setting
LED indication
Temperature sensor ( )
PMV openness
(pulse)
Current
(A)
less than -25
-25 - -21
-20 - -16
-15 - -11
-10 - -6
-5 - -1
0 - 4
5-9
10-14
15-19
20-24
25-29
30-34
35-39
40-44
45-49
50-54
55-59
60-64
65-69
70-74
75-79
80-84
85-89
90-94
95-99
100-104
105-109
110-114
115-119
120 or higher
sensor failure, not connected
0-0.9
1-1.9
2-2.9
3-3.9
4-4.9
5-5.9
6-6.9
7-7.9
8-8.9
9-9.9
10-10.9
11-11.9
12-12.9
13-13.9
14-14.9
15-15.9
16-16.9
17-17.9
18-18.9
19-19.9
20-20.9
21-21.9
22-22.9
23-23.9
24-24.9
25-25.9
26-26.9
27-27.9
28-28.9
29-29.9
30-30.9
31 or higher
0-4
5-9
10-14
15-19
20-24
25-29
30-34
35-39
40-44
45-49
50-54
55-59
60-64
65-69
70-74
75-79
80-84
85-89
90-94
95-99
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-144
145-149
150-154
155 or higher
0-19
20-39
40-59
60-79
80-99
100-119
120-139
140-159
160-179
180-199
200-219
220-239
240-259
260-279
280-299
300-319
320-339
340-359
360-379
380-399
400-419
420-439
440-459
460-479
480-499
500
-
-
-
-
-
-
Compressor
operation
frequency
(r.p.s.)
1234
ON
SW803
1234
ON
SW803
1234
ON
SW803
1234
ON
TD
SW803
1234
ON
TE
SW803
1234
ON
TS
SW803
1234
ON
TO
SW803
1234
ON
TH
SW803
1234
ON
TA
SW803
1234
ON
TC*
SW803
1234
ON
TCJ
SW803
*See p122
1234
ON
TL
SW803
Legend)
----
Off
----
Light
D800 (Y
ellow)
D801 (Y
ellow)
D802 (Y
ellow)
D803 (Y
ellow)
D804 (Y
ellow)
D805 (Green)
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 124 Monday, October 5, 2009 2:09 PM