e-STUDIO203S/203SD TEST COMMAND, TROUBLE CODES 10 - 16
41
06
OC cover float detection
level adjustment (OC FLOAT
LEVEL)
[Function]
When this test command is executed, the current set value is displayed. When [ENTER/START]
key is pressed, the mirror base unit moves to the ADF scan position to acquire the OC cover
float detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the detection level is not acquired, ERR display is made. (Default: 0)
Note that, this test command must be executed with the OC cover closed.
∗
If the value is 0, float detection is not performed in normal jobs.
[Operation]
07
OC cover float detection
margin setting (OC FLOAT
MGN)
[Function]
For the number of pixels between black markers on the ADF scanning position saved in “41-06:
(OC cover float detection level adjustment)”, if the number of pixels between the markers when
processing float detection is less than the number of pixels set with this simulation, it is judged
as the float error.
When the set value of this test command is "0," no float error occurs.
When this test command is executed, the current set value is displayed.
Enter the adjustment value with 10-key, and press [START] key. The setting is saved and the
display is shifted to the sub code input standby menu.
Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.)
Default: 30 (30 pixels)
[Operation]
The operation is similar to test command 9-04.
43
01
Fusing temperature setting
(Normal copy) (FU TEMP)
[Function]
When this test command is executed, the current set code number is displayed. Press [
←
/
→
/
10KEY] key to change the setting and press [ENTER/START] key to save the setting into the
EERPOM. The machine goes into the sub code entry standby mode.
∗
The cassette feed and the manual feed are controlled similarly.
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
1) Initial display
2) [ENTER/START]
41-06 OC FLOAT LEVEL
0
41-06 OC FLOAT LEVEL
EXECUTING...
<Canceling - when C/CA key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
3) When the level is acquired:
3) When the level is not acquired:
THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
**** OK
41-06 OC FLOAT LEVEL
**** ERR
Code
Set temperature (°C)
Remark
0
170
1
175
2
180
3
185
4
190
Default
5
195
6
200
7
205
8
210
Mode
Display item
Main cassette paper feed & 2nd cassette paper feed
TRAY1
Manual paper feed
MFT
1) Initial display <Main cassette paper feed
& 2nd cassette paper feed setting>
2) [
←
/
→
] Mode selection
3) [10KEY] Value entry
4) [ENTER/START] Settles the entered
value. The display is shifted to the sub
code input standby menu.
43-01 FU TEMP
TRAY1 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )
43-01 FU TEMP
MFT 7( 0-8 )