7 CHECKING THE EQUIPMENT STATUS WITH TopAccess
90 Error Codes
2C44
Creating a file was not allowed
Creating an unencrypted file was not allowed.
Configure the encryption settings and try again. To
create an unencrypted file, consult the administrator.
2C45
Failure in making meta data
Make sure that the template setting is correct, and do
the scanning again. If the error still persists, turn the
power OFF and then back ON, and then try again.
2C60
HDD full failure during processing
Reduce the number of pages of the problem job and try
again. Check whether the server or local disk has
sufficient space in its capacity.
2C61
Failure to read Address Book
Turn the power OFF and then back ON. Try the
problem job again. Reset the data in the Address Book
and reattempt it. If the error still persists, contact your
service representative.
2C63
Terminal IP address unset
Ask your administrator to set the IP address of the
equipment.
2C64
Terminal mail address unset
Ask your administrator to set the Email address of the
equipment.
2C65, 2C66,
2C69
Failure to connect to SMTP server
Make sure that the SMTP server is correctly working or
the SMTP server address has been set correctly.
2C6A
Failure to send Email message
Turn the power OFF and then back ON. Try scanning
again. If the error still persists, contact your service
representative.
2C6B
Invalid address specified in From: field
Ask your administrator to check the SMTP
Authentication method or if there is an unpermitted
character in the Terminal mail address. Set the correct
SMTP Authentication method or delete the unpermitted
character in the Terminal mail address.
2C6C
Invalid address specified in To: field
Make sure that there is no unpermitted character in the
Destination mail address. Delete any unpermitted
character and reset the appropriate Destination mail
address, then try again.
2C70
SMTP service is not available
Ask your administrator whether the SMTP service is
enabled.
2C71
SMTP authentication error
Confirm that the login name and password are correct.
If SSL is enabled, make sure that the SSL port number
is correctly set.
2C72
POP Before SMTP error
Confirm that the POP Before SMTP settings and POP3
settings are correct.
2CC0
Job canceled
The job was canceled.
2CC1
Power failure occurred
Make sure that the power cable is connected properly
and is inserted securely. Resend the job.
Save as File
2D10, 2D12,
2D13
Wrong Job status
Turn the power OFF and then back ON. Try it again. If
the error still persists, contact your service
representative.
2D11
Not enough memory
Wait for a while and try again. If the error still persists,
turn the power OFF and then back ON, and make
another effort.
2D14
Invalid parameter specified
If you are using a template, create it again. If the error
still persists, turn the power OFF and then back ON,
and then try again.
2D15
Exceeding maximum file capacity
Divide the file into several files, or try again in a single-
page format.
2D30
Failure to create directory
Make sure that the access privilege to the storage
directory is writable and also that the disk in the
directory has enough space, and then try again. If more
than one job is performed simultaneously, the error may
occur because the disk temporarily runs out of space. In
this case, wait for a while and try again. If the error still
persists, turn the power OFF and then back ON, and
make another effort.
Error Code
Problem Description
Corrective Action