DigitalIOControl
This section describes DigitalIOControl category for the BU series.
This camera provides GPIO output selected by the register setting. And the polarity of the signal is able to
switch by the register setting. The following chart shows the specifications of the selectable signals.
Fig. Selectable signals
●
Registers
Register
Visibility
Access
Description
LineModeAll
Beginner
R
Returns the direction of each Line signal.
LineInverterAll
Beginner
R/W
Selects the polarity of each Line signal.
LineStatusAll
Beginner
R
Returns the status of each Line signal.
UserOutputValueAll
Beginner
R/W
Sets the user output value.
LineSelector
Beginner
R/W
Selects the Line of I/O connector.
LineSource
Beginner
R/W
Selects the source of the output signal.