47 / 65
D4223121B
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
www.toshiba-teli.co.jp
●
Registers
Register
Visibility
Access
Description
UserSetSelector
Beginner
R/W
Selects a bank of user setting.
UserSetLoad
Beginner
W
Executes load a user setting.
UserSetSave
Beginner
W
Executes to save a user setting.
UserSetDefault
Beginner
R/W
Selects a bank of user setting when camera powers up.
●
Setting
- Select a bank of a user setting
Set the following value to “UserSetSelector” register. The setting value is Enumeration type.
Select the bank of user setting for “UserSetLoad” and “UserSetSave”.
setting value
Description
Save
Load
UserSet0 (*)
Select memory bank 0 for user setting.
○
○
* initial factory setting
- Load/Save a user setting
When execute “UserSetLoad”, the camera loads user setting from the bank selected in “UserSetSelector”
register and applies them.
When execute “UserSetSave”, the camera saves user setting to the bank selected in “UserSetSelector”
register.
- Load a user setting at the time of start-up
Set the following value to “UserSetDefault” register. The setting value is Enumeration type.
The camera loads user setting from the bank selected in “UserSetDefault” register and applies them at the
time of next start-up.
“UserSetDefault” register value is stored to non-volatile memory when it is selected.
setting value
Description
Default (*)
Memory bank to read initial factory setting data.
UserSet0
Memory bank 0 for user setting.
* initial factory setting
●
Note