background image

Operating instructions 

3D camera

O3X120 

O3X130 

O3X16x 

O3X18x

11489236 / 00

 

11 / 2022

UK

Summary of Contents for O3X16 Series

Page 1: ...Operating instructions 3D camera O3X120 O3X130 O3X16x O3X18x 11489236 00 11 2022 UK...

Page 2: ...temperature 10 5 3 Install device 10 6 Electrical connection 11 6 1 Wiring 11 6 2 Use of several devices 12 7 Set up 12 7 1 Set parameters of the device 12 7 2 Optimum object detection 13 7 3 Install...

Page 3: ...t settings 20 7 7 4 Install firmware update 21 7 7 5 Network 22 7 7 6 NTP 23 8 Programming example 24 8 1 ifm3Dlib 24 9 Maintenance repair and disposal 25 9 1 Cleaning 25 9 2 Replace device 25 10 Appr...

Page 4: ...tire duration of use of the device For a detailed description of the associated software please read the software manual and the interface description 1 1 Explanation of symbols Instructions Reaction...

Page 5: ...Free Software Foundation If version 1 applies to the software either version 1 of the License or at your option any later version if version 2 or 2 1 applies to the software either version 2 or 2 1 of...

Page 6: ...in the memo line of your payment Your request should include i the name of the covered binary ii the name and the version number of the ifm product iii your name and iv your return address This offer...

Page 7: ...ional and international standards Responsibility lies with the person installing the device Only the signals indicated in the technical data or on the device label may be supplied to the connections o...

Page 8: ...ng of the device is also done via Ethernet The device safety is rated for use under the following operating conditions Indoor use Altitudes up to 2000 m Relative air humidity up to max 90 non condensi...

Page 9: ...ng the object When determining the distance between device and object take the measuring range of the device into account The measuring range is indicated in the data sheet of the sensor Select a dist...

Page 10: ...uctive metal parts A large surface contact of the device with metal parts increases heat dissipation e g conventional aluminium heat sinks or profiles Reduce obstructions around the device Reduce the...

Page 11: ...ion class III PC III The electrical supply must only be made via PELV circuits For cable lengths 30 m use an additional protection against surge voltages to IEC 6100 4 5 Disconnect power before connec...

Page 12: ...heless measurement errors and minor tolerances may occur 7 Set up After power on the device is put into operation After 15 seconds the device is in the evaluation mode where saved applications are exe...

Page 13: ...lowing conditions are met Object is positioned in the field of view Object is the nearest visible object to the device Unambiguous range is clear from objects obstructions etc Lens window of the devic...

Page 14: ...3 4 1 Power supply 24 V 2 Device 3 Ethernet cable 4 PC 7 4 3 Connect device automatically 1 Start the ifmVisionAssistant application 2 Click on Start the ifmVisionAssistant application The ifm Vision...

Page 15: ...nnection to the device has been established ifm Vision Assistant opens the monitoring screen In the monitoring screen the device runs in the operating mode The current application can be monitored but...

Page 16: ...n rate is changed in the input box Target Framerate The max possible image repetition rate depends on the exposure mode and the exposure time Process interface The device is controlled via the process...

Page 17: ...exposure is intended for scenes with low dynamics The exposure time is set in s The value is changed with the slider bar or entered in the box If an Image Setting Type is set with 2 exposure times the...

Page 18: ...Temporal Filter optimise the repeatability The list Spatial Filter contains the following filters Filter Description Characteristics Median filter Each pixel is replaced by the median of the neighbour...

Page 19: ...et in the window General Field Button Description Name Set the name of the device Description Set the description of the device Password protection On Off standard Activate or deactivate the password...

Page 20: ...settings The settings of the ifm Vision Assistant can be exported for the firmware update or the exchange of the device 1 Click on the button Export The Save as window appears 2 Enter File name for t...

Page 21: ...re available on our website www ifm com Update the firmware 1 Click on the button Update 2 Acknowledge message window with OK The file selection window is displayed 3 Select firmware file The firmware...

Page 22: ...f the device The default setting is 192 168 0 69 Subnet mask Input box Set the subnet mask of the network The default setting is 255 255 255 0 Gateway Input box Set the gateway of the network The defa...

Page 23: ...and the time from the network NTP server green The set NTP server answered to the last request NTP server red The set NTP server did not answer to the last request NTP server grey The set NTP server h...

Page 24: ...Camera MakeShared auto fg std make_shared ifm3d FrameGrabber cam ifm3d IMG_AMP ifm3d IMG_RDIS ifm3d IMG_CART auto img std make_shared ifm3d ImageBuffer if fg WaitForFrame img get 1000 std cerr Timeou...

Page 25: ...vice Use clean and lint free cloth If the instructions are not observed scratches on the lens window may cause measurement errors 9 2 Replace device The parameters are lost when a device is replaced C...

Page 26: ...IP address After saving the settings the ifm Vision Assistant tries to establish the connection automatically 1 Reboot ifm Vision Assistant 2 Click on The ifm Vision Assistant searches for connected...

Reviews: