16
7.6.1 Set trigger source
The trigger source is set in the list "Trigger"
The following trigger sources can be set:
Trigger
source
Description
Continuous
The trigger source "Continuous" displays the current image
repetition rate in the window "Image settings". The image
repetition rate is changed in the input box "Target Framerate".
The max� possible image repetition rate depends on the
exposure mode and the exposure time�
Process
interface
The device is controlled via the process interface
(e�g� PC)�
7.6.2 Set capture mode
The capture mode is set in the list "Image Setting Type". In the capture mode the
characteristics of an image capture are set�
The capture mode
"upTo30m_moderate" is preset:
• Unambiguous range
"30 m"
• 2 measurement
frequencies
• 2 exposure times