2. PRINTER SETUP
ENGLISH VERSION EO1-33094
2.9 Position and Print Tone Fine Adjustment
E2-67
2.9.1 Fine Adjustment (Cont.)
(8) RBN ADJ.<BK>
When the ribbon is slack or wrinkled and printing is affected,
fine adjust the ribbon motor torque.
(9) THRESHOLD <REFL.>
When you perform a threshold setting for the reflective sensor and
found the threshold needs to be adjusted, set a fine adjustment
value.
This menu is accessible directly from the Threshold Setting Mode
so that the threshold can be manually set right away.
Manually set threshold = Peak voltage – The value set here
For details, refer to
Section 2.10
.
(10) THRESHOLD <TRANS.>
When you perform a threshold setting for the Transmissive sensor
and found the threshold needs to be adjusted, set a fine
adjustment value. This menu is accessible directly from the
Threshold Setting Mode so that the threshold can be manually set
right away. .
Manually set threshold = Peak voltage – The value set here
For details, refer to
Section 2.10
.
+10
-15
+9
-14
High
Low
Motor torque
NOTE:
When “0.0 V” is set for this
parameter, it is automatically
corrected to 1.4V (default)
after the power is turned OFF
then ON.
NOTE:
When “0.0 V” is set for this
parameter, it is automatically
corrected to 1.0V (default)
after the power is turned OFF
then ON.
4.0V
0.0V
3.9V
0.1V
4.0V
0.0V
3.9V
0.1V
NOTE:
1. The fine adjustment value is
not effective for the reverse
rotation.
2. The all fine adjustment
values are applicable to
every print speed.