Error messages
8
Error messages
Drive system
Display
Cause
What to do
E02
Stator excess temperature (motor overheated)
After waiting for a short period (approx. 10 minutes), motor can be operat-
ed slowly again.
Contact Torqeedo Service.
E05
Motor/propeller blocked
Put the main switch into the "OFF" position, and disconnect the batteries.
Release the blockage, and turn the propeller one further turn by hand.
Reconnect the batteries to the system.
E06
Voltage to motor is too low
Low state of charge of battery. It may be possible to restart the motor
slowly from the Stop position.
E07
Overcurrent to motor
Continue at reduced power.
Contact Torqeedo Service.
E08
Circuit board excess temperature
After waiting for a short period (approx. 10 minutes), motor can be operat-
ed slowly again.
Contact Torqeedo Service.
E09
Water ingress to pylon
Contact Torqeedo Service.
page 100 / 121