Troubleshooting
For all electrical problems, the use of the quick refer
ence troubleshooting method is recommended. Using
the Diagnostic ACE
TM
Display allows you to quickly find
the source of the electrical problem.
For intermittent electrical problems, which are not
repeatable, use of the Data Log System is recom
mended. The data log system records the actual state
of machine inputs and outputs at the time of malfunction.
Your Toro Distributor can then isolate the cause of the
electrical problem.
Quick Reference Troubleshooting Guide
Controller Diagnostic Lamp
NOTE: See “Using the Diagnostic ACE” book, Form
92-800-SL for more information.
Controller Diagnostic Lamp
Before doing any troubleshooting, check green control
ler diagnostic lamp. If diagnostic lamp is
ON, with key
switch in RUN position, the electronic control unit (ECU)
is functioning normally.
If diagnostic lamp is
FLASHING ON and OFF:
1. ECU has detected an output with a short circuit.
2. ECU has detected an output with an open circuit.
Use diagnostic display to find which output is malfunc
tioning.
If the diagnostic lamp is
OFF:
1. Loop-back connector is not attached.
2.
Diagnostic
light is burned out.
3. ECU is not powered on.
4. ECU is not functioning correctly.
Check electrical connections, input fuses and diagnos
tic light to find malfunction. Make sure loop-back con
nector is secured to wire harness connector.
Diagnostic ACE
TM
Display
Use diagnostic display tool to verify correct electrical
functi on of the machine and to locate electrical
malfunctions.
1. Park machine on a level surface, engage parking
brake, lower cutting units and turn ignition key
switch off.
2. Carefully disconnect loop-back connector from wire
harness (Fig. 7).
3. Connect diagnostic display tool to communication
connector on wiring harness (where loop-back connec
tor was removed). Make sure correct overlay decal is
installed on diagnositc display.
4. Turn ignition key switch ON, but DO NOT start the
engine.
Reelmaster
®
5100-D
5. The “
INPUTS DISPLAYED
” LED, on lower right column
of diagnositc display, should be on. If necessary, push
input-output toggle switch on diagnostic display so
“
INPUTS DISPLAYED
” LED is on. Do not hold the button
down.
NOTE: Red text on overlay decal refers to input
switches and green text to outputs.
2
1
3
Figure 7
1.
Wire
harness
and
connector
2.
Loop-back
connector
3.
Controller diagnostic lamp
1
Figure 8
1. Diagnostic ACE
TM
Display
Page 5 - 7
Rev. A
Troubleshooting
Summary of Contents for Reelmaster 5100-D
Page 2: ...This page is blank ...
Page 4: ...This page is blank ...
Page 8: ...Safety Instructions Page 1 4 Reelmaster 5100 D ...
Page 12: ...Maintenance Interval Chart Maintenance Interval Chart Page 2 4 Rev A Reelmaster 5100 D ...
Page 32: ...Troubleshooting Page 3 16 Reelmaster 223 D 5100 D ...
Page 33: ...Reelmaster 223 D 5100 D Page 3 17 Troubleshooting ...
Page 86: ...Specifications Page 4 2 2 Reelmaster 5100 D ...
Page 90: ...Hydraulic Schematic Rev A Hydraulic Schematic Page 4 6 Reelmaster 5100 D ...
Page 154: ...Logic Chart Page 5 2 Reelmaster 5100 D ...
Page 155: ...Wiring Schematic S N Below 51001 Rev B Reelmaster 5100 D Page 5 3 Wiring Schematic ...
Page 206: ...Repairs Page 5 48 Rev A Reelmaster 5100 D ...
Page 230: ...Repairs Page 6 24 Reelmaster 5100 D ...
Page 304: ...Repairs Page 8 22 Reelmaster 223 D 5100 D 5300 D ...
Page 317: ...This page is blank ...