Clearing Active Machine Faults
1. Resolve the active fault(s).
2. While in diagnostic mode (shunt connectors together), set the key switch
to the R
UN
position.
3. Disconnect the diagnostic shunt connectors, then reconnect them. The
diagnostic light will flash continuously once per second if all the active faults
have been cleared.
4. Set the key switch to the O
FF
position.
Exiting Diagnostic Mode
1. Set the key switch to the O
FF
position.
2. Disconnect the diagnostic shunt connectors and install the tethered cap.
3. Store the diagnostic connector assembly in the control tower.
Pro Force® Debris Blower
Page 3–5
Troubleshooting: General Operation Problems
18237SL Rev A