ST-700-DR-E / ST-701-DR-E

Industrial Fan Blower

92-100-0001-13 

Summary of Contents for ST-700-DR-E

Page 1: ...ST 700 DR E ST 701 DR E Industrial Fan Blower 92 100 0001 13 ...

Page 2: ...nacle Climate Technologies Inc 668 Stony Hill Road 302 Yardley PA 19067 Read The Instruction manual When this symbol is marked on a product it means that the instructon manual must be read 1 ENGLISH 1 3 7 10 11 ...

Page 3: ... 2016 Pinnacle Climate Technologies Inc 668 Stony Hill Road 302 Yardley PA 19067 1 1 2 2 3 3 5 4 6 ST 700 DR E ST 701 DR E 2 1 Front Guard 2 Handle 3 Power Cord 4 Power Switch 5 Power Knob 6 Cord Wrap ...

Page 4: ...to switch the ventilator off in an emergency ALWAYS use only the electrical power voltage and frequency specified on the model plate of the ventilator ALWAYS use an extension cord properly rated for this appliance ALWAYS install the ventilator so that it is not directly exposed to water spray rain or dripping water ALWAYS ensure that all cords are protected against short circuit and overload ALWAY...

Page 5: ...ower produces a flat air column which is well suited for drying and evaporating excess moisture from floors NOTE This blower will not prevent mold or mildew formation To prevent mold or mildew formation this blower should be used in unison with a dehumidifier Ventilation and Cooling This blower can drop the temperature of an over heated room by moving large quantities of air rapidly Stacking The h...

Page 6: ...e Neutral Brown Live Green Yellow Earth As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plug proceed as follows The blue wire must be connected to the terminal marked with an N or colored black The brown wire must be connected to the terminal marked with an L or colored red The green yellow wire must be c...

Page 7: ...ctrical elements do get wet they must be dried immediately Problem Possible Cause Solution Motor does not run 1 No power supply to the device 2 Switch knob not turned on 3 Fan wheel blocked 4 Air inlet or outlet is blocked 5 Switch is broken 6 Loose wiring 1 Connect device check fuse 2 Turn knob on press power switch to ON 3 Inspect fan wheel and remove blockage 4 Remove blockage and clean air inl...

Page 8: ... 1 2 3 4 5 6 8 9 7 ST 700 DR E ST 701 DR E Parts List ST 700 DR E ST 701 DR E 1 92 003 0010 92 003 0020 2 92 008 0010 92 009 0011 3 92 001 0010 92 001 0020 4 92 002 0010 92 013 0010 5 92 024 0010 92 008 0020 6 92 002 0010 92 025 0020 7 92 009 0001 92 024 0020 8 92 025 0010 92 026 0020 9 92 026 0010 92 002 0020 7 ...