Starting Problems (continued)
Problem
Possible Cause
Corrective Action
The fuel tank is empty
Fill the fuel tank
The engine and/or fuel is too cold
Use the choke to start the engine
Move the machine to a heated
environment prior to starting
The fuel filter is plugged
Replace the fuel filter
The fuel pump is damaged
Test the pulse fuel pump and
repair/replace it if necessary; refer
to the Kohler Command Pro CH740
Service Manual for pulse fuel pump
information
Fuse F–2 (7.5 A) is damaged
Test the fuse and replace it if necessary;
refer to Fuses in Chapter 5 – Electrical
System
The Governor Control Unit (GCU) has
lost power
Clean, secure or repair/replace the
circuit wiring; Refer to the Electrical
Schematics in Appendix A
The fuel/carburetor solenoid or its
circuit wiring is damaged
Test the carburetor solenoid and
replace it if necessary; refer to the
Kohler Command Pro CH740 Service
Manual for fuel shut-off solenoid
information
Clean, secure or repair/replace the
circuit wiring; Refer to the Electrical
Schematics in Appendix A
The engine cranks, but does not start
The engine is malfunctioning
Troubleshoot the engine; refer to the
Kohler Command Pro CH740 Service
Manual
Pro Force® Debris Blower
Page 3–7
Troubleshooting: Starting Problems
18237SL Rev A
Summary of Contents for Pro Force 44552
Page 4: ...Reader Comments Page 4 Pro Force Debris Blower 18237SL Rev A ...
Page 8: ...Preface Page 8 Pro Force Debris Blower 18237SL Rev A ...
Page 28: ...Specifications and Maintenance Special Tools Page 2 14 Pro Force Debris Blower 18237SL Rev A ...
Page 54: ...Engine Service and Repairs Page 4 16 Pro Force Debris Blower 18237SL Rev A ...
Page 98: ...Electrical System Service and Repairs Page 5 44 Pro Force Debris Blower 18237SL Rev A ...