InfoCenter Advisories

Operator advisories automatically display on the InfoCenter screen when a machine function requires additional action. For
example, if you attempt to start the engine while pressing the traction pedal, an advisory displays, indicating that the traction
pedal must be in the N

EUTRAL

position.

For each advisory that occurs, there is a condition (e.g., start prevent, engine stopped), an advisory code (number), a qualifier
(the cause of the advisory displayed), and a display text (what the advisory displays as text on the screen) as shown in

Figure 29

.

Figure 29

1.

Display text

3.

Press any key on the InfoCenter to clear the text from the
display screen.

2.

Code

Note:

Advisories do not log into the fault log.

Note:

You can clear an advisory from the display screen by pressing any of the InfoCenter keys.

Refer to the following table for all the InfoCenter advisories:

Condition

Code

Qualifier

Display Text

Start Prevented

2

Pump switch active

To start, turn pump off

Start Prevented

3

Not in N

EUTRAL

To start, return traction pedal to
neutral

Start Prevented

4

Out of seat

To start, must be seated or set
the parking brake

Start Prevented

5

Starter engage timeout

To start, rest starter

Start Prevented

6

Rinse pump active

To start, turn off rinse pump

Engine Stopped

102

Out of seat

Engine stop due to operator out
of seat

Engine Stopped

103

Parking brake set

Engine stop due to parking
brake engaged

Pump Start Prevented

202

Boom active

To start pump, turn booms off

Pump Start Prevented

203

Out of seat and parking brake
not set

To start pump, must be seated
or set parking brake

Pump Start Prevented

205

Engine starting

To start pump, stop cranking
engine

Pump Turned Off

206

Out of seat

To start pump, remain seated

Tank Status

402

Low spray tank volume

Tank status, volume low

Tank Status

403

Rinse pump active

Tank status, rinse pump on

Parameter Status

502

Wrong parameter value entered

Parameter status, invalid value

14

 

Summary of Contents for 41642

Page 1: ...ard against personal contact with a chemical There may be more than 1 chemical used and information on each chemical should be assessed Refuse to operate or work on the sprayer if this information is...

Page 2: ...er 4 Remove the clamps gaskets and manifold coupler Figure 1 Note Retain the clamps 5 Install the flow meter and 2 flow meter gaskets using the clamps that you just removed Figure 1 6 Remove the trans...

Page 3: ...Switch 2 Plug 10 Install the switch into the hole Figure 4 11 Beneath the dashboard connect the wire harness to the switch then connect it to the machine wire harness Note The connector on the machine...

Page 4: ...2 13 14 15 G035692 Figure 5 1 Master boom switch indicator on 5 Tank volume indicator US gallons 9 Selected application rate boost rate indicator on 13 Active application rate gpa 2 Right boom section...

Page 5: ...at Figure 5 Selected Application Rate Boost Rate Indicator The selected application rate boost rate indicator displays when either the selected application rate and or the boost rate are active Figure...

Page 6: ...usly to select Rate 1 or press and hold buttons 4 and 5 simultaneously to select Rate 2 Note From the Home screen press and hold buttons 1 and 5 simultaneously to apply boost rate Boost is active only...

Page 7: ...3 Press button 1 or 2 until you reach the desired unit and then press button 4 to select this unit English mph gallons acre Turf mph gallons 100 ft SI metric kph liter hectare Change the InfoCenter d...

Page 8: ...5 Enter PIN 3 Digit 3 3 From the PIN Settings screen press button 4 to select PIN Entry and to turn the PIN on or off Figure 16 Figure 16 Change the InfoCenter PIN as follows 1 Press button 2 on the...

Page 9: ...Enter your new PIN using buttons 1 to 4 and press button 5 when you complete your new PIN Figure 19 Figure 19 1 Digit 1 4 Digit 4 2 Digit 2 5 Enter PIN 3 Digit 3 6 Confirm your new PIN using buttons 1...

Page 10: ...ctions must be on when performing the catch test 8 Start at 2 75 bar 40 psi and use the application rate switch to adjust the spray pressure so a catch test yields the volume displayed for the selecte...

Page 11: ...a Calibration Successful screen appears press button 5 to exit 12 If the calibration is not successful a Calibration Failed screen appears with the reasoning behind why the calibration failed press b...

Page 12: ...ect About Figure 26 This screen displays the model number and serial number of your machine G034285 Figure 26 InfoCenter Spray Area Screens From the Home screen press and hold button 5 to open the men...

Page 13: ...ub area 4 Volume sprayed in the active sub area US gallons 2 Area sprayed in the active sub area acres 5 Select the previous sub area hold the button to reset area and volume sprayed for the active su...

Page 14: ...isories Condition Code Qualifier Display Text Start Prevented 2 Pump switch active To start turn pump off Start Prevented 3 Not in NEUTRAL To start return traction pedal to neutral Start Prevented 4 O...

Page 15: ...Parameter Status 503 A value is outside the range of accepted values Parameter status invalid data defaults used Booms Turned Off 802 Speed dropped Booms turned off stopped or moving too slowly 15...

Page 16: ......

Reviews: