InfoCenter Advisories
Operator advisories automatically display on the InfoCenter screen when a machine function requires additional action. For
example, if you attempt to start the engine while pressing the traction pedal, an advisory displays, indicating that the traction
pedal must be in the N
EUTRAL
position.
For each advisory that occurs, there is a condition (e.g., start prevent, engine stopped), an advisory code (number), a qualifier
(the cause of the advisory displayed), and a display text (what the advisory displays as text on the screen) as shown in
.
Figure 29
1.
Display text
3.
Press any key on the InfoCenter to clear the text from the
display screen.
2.
Code
Note:
Advisories do not log into the fault log.
Note:
You can clear an advisory from the display screen by pressing any of the InfoCenter keys.
Refer to the following table for all the InfoCenter advisories:
Condition
Code
Qualifier
Display Text
Start Prevented
2
Pump switch active
To start, turn pump off
Start Prevented
3
Not in N
EUTRAL
To start, return traction pedal to
neutral
Start Prevented
4
Out of seat
To start, must be seated or set
the parking brake
Start Prevented
5
Starter engage timeout
To start, rest starter
Start Prevented
6
Rinse pump active
To start, turn off rinse pump
Engine Stopped
102
Out of seat
Engine stop due to operator out
of seat
Engine Stopped
103
Parking brake set
Engine stop due to parking
brake engaged
Pump Start Prevented
202
Boom active
To start pump, turn booms off
Pump Start Prevented
203
Out of seat and parking brake
not set
To start pump, must be seated
or set parking brake
Pump Start Prevented
205
Engine starting
To start pump, stop cranking
engine
Pump Turned Off
206
Out of seat
To start pump, remain seated
Tank Status
402
Low spray tank volume
Tank status, volume low
Tank Status
403
Rinse pump active
Tank status, rinse pump on
Parameter Status
502
Wrong parameter value entered
Parameter status, invalid value
14