background image

3PL Small Frame

Operator’s & Parts Manual

GA8701054 REV 0 - APR 2019

Summary of Contents for 3PL 1000L

Page 1: ...3PL Small Frame Operator s Parts Manual GA8701054 REV 0 APR 2019 ...

Page 2: ...ction 14 Spray Control Manifold 16 Electric Controls 17 Control station taps 19 Calibrating your sprayer 20 Nozzle Calibration 20 Tasks prior to spraying 21 Chemical Probe 22 Transporting Sprayer 23 End of Spraying Day Tasks 24 End of Season Tasks 24 Folding Booms 25 Filters 26 Diaphragm Pump 27 Diaphragm Pump Zeta 70 29 Diaphragm Pump Zeta 85 30 Diaphragm Pump Troubleshooting 31 Filling 34 Spray ...

Page 3: ...acres not only produce Australia s finest range of spraying equipment we also keenly value the unique relationship we enjoy with owners of our equipment We are pleased to welcome you as a Goldacres owner and look forward to making your spray applications as efficient as possible Please use this comprehensive resource to gain a full understanding of your equipment and don t hesitate to contact your...

Page 4: ...anufacturer s specifications be checked and all instructions for use when transporting or towing be adhered to at all times Care should be taken when transferring liquid into the tank to ensure that the gross weight of the equipment does not exceed the carrying braking and or towing capacity of the vehicle to which the equipment is attached as specified by the vehicle manufacturer NOTE 1 LITRE WAT...

Page 5: ...road regulations when transporting When draining fluids from the equipment use appropriate leak proof containers Do not use food or beverage containers as someone may consume the contents by mistake After reading the operator s manual if there is any thing that you do not understand please contact your Goldacres dealer Safe Chemical Use The safe use of Ag chemicals with this equipment is the respo...

Page 6: ...ls are there for your protection and it is the responsibility of the owner operator to replace damaged and or missing safety decals Regularly review safety decals with operators It is very important to ensure that all new machine components and replacement parts include current hazard identification decals Replacement safety decals can be ordered from all Goldacres dealers Part No Description GA87...

Page 7: ... housing Hydraulics Axle frame only Shockers and dampeners Wire cables Springs Drive chains Wheel bearings Failure caused by lack of lubrication not covered Warranty Exclusions Pump diaphragms Pump Seals Pump check valves Pump O rings Filters and filter screens Filter O rings Chemical Hoses Solenoid Diaphragms Hand Gun lance or wand seals and O rings Consumables chemicals fuels Items controlled by...

Page 8: ...anship or materials used under normal use and service conditions The Warranty is not transferable The owner is responsible for the performance of regular maintenance and service as specified in the owner s operators manual applicable to the product Failure to follow regular maintenance as advised may invalidate the warranty The owner must provide the Goldacres Dealer with prompt written notice of ...

Page 9: ...rchaser is entitled to at law which cannot be excluded by these terms and conditions and in all other cases b making good any defects by repairing the same or at Goldacres option by replacement within a period not exceeding either 1000 hours or twelve calendar months whichever comes first after the Goods have been dispatched provided that i the defects have arisen solely from faulty materials or w...

Page 10: ...h ranking whether by act or omission 3 The Purchaser acknowledges that it has received value as at the date of first delivery of the Goods and has not agreed to postpone the time for attachment of the security interest as defined in the PPSA granted to Goldacres under these terms and conditions 4 The Purchaser will execute documents and do such further acts as may be required by Goldacres to regis...

Page 11: ... polyethylene Polyethylene tanks have a very high chemical resistance Due to the rotomoulding process there can be a variance in the overall dimensions of the tank which in turn results in variations to the tank capacity For this reason calibration markings should be used as a guide only Paint Colours Steel work G13 Dark Green Pump The pump is critical to any sprayer performance Correct operation ...

Page 12: ...1475mm 1614mm 2104mm 1614mm 2465mm 1058mm 1355mm 1383mm 1005mm 1547mm 1218mm 1439mm 1826mm 1689mm 1671mm 3PL 600L 6m Boom 3PL 800L 8m Manual Dual Fold Boom 3PL 800L 3PL 1000L 3PL 450L Model Weight 450 L 150 kg Empty no booms 600 L 180 kg Empty no booms 800 L 190 kg Empty no booms 1000 L 240 kg Empty no booms ...

Page 13: ... fitted 15 Manifold pressure gauge 16 Agitator if fitted F E ITEM 1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 4 4 MATERIAL MATERIAL SPECIFIED THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINI WEIGHT UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES DEBURR A SHARP 262 98 KG UNLESS OTHERWISE SPECIFIED 0 1 ...

Page 14: ...ages 1 Remove from pallet if attached and position on a solid flat surface 2 Lower the tractors linkage arms to a height appropriate for connection to the sprayer s lower linkage pins and then connect the tractors top link to the top linkage pin of the sprayer 3 Make sure that all securing pins are in place prior to raising 3PL 4 Lift 3PL to intended spray height and then adjust linkage top link t...

Page 15: ...purpose grease should be used for all lubrications The figures mentioned below refer to the frequency in hours of lubrication for the respective grease nipple locations Pull shaft apart apply grease to inside of outer Telescopic profile 6 Check pump oil level prior to engaging PTO 7 Fill the tank with a quantity of water sufficient to test spray unit for leaks 8 Unfold the boom as per the boom fol...

Page 16: ...nder very low pressure the dump valve needs to be pushed back against the tank Boom Attachment Levers The boom attachment levers number fitted dependent on options specified open or close flow to the appropriate boom section s or attachment s as labeled Pull the lever to the ON position in order to direct flow from the pump to the required function Push the lever to the OFF position to stop flow g...

Page 17: ...ositive power wire is fitted with a 10A fuse It is important that this fuse remain in the wiring loom when wiring into the tractor as a safety protection fuse for both tractor and console The second wiring loom coming from the console connects to the wiring harness mounted on the sprayer It is important to route the sprayer harness into the tractor through the appropriate rubber cabin grommets and...

Page 18: ... open To open the dump valve simply push the red handle back towards the tank To close the dump valve pull the red handle forwards bringing the handle out All sprayer functions including boom operation hose reel or suction probe will not operate with the dump valve open to bypass picture 3 showing the dump valve open Pressure regulator The manual pressure relief valve provides pressure adjustment ...

Page 19: ...f bypass back to the spray tank The boom section valves are wired and plumbed in the same sequence as the control console with section 1 being the left section Troubleshooting Electric Boom Valves Display Cause Solution The LED s illuminate on the console but the valves do not open Connectors not connected or unplugged Connect the connectors in the correct way Damaged cable Replace The LED s are o...

Page 20: ...zzle output l min x 10 000 rate L Ha Spray width m x speed m min Nozzle Selection Refer to the chemical manufacturer s information to determine the recommended application rate in litres per hectare l ha for your particular situation Then determine the speed in kilometres per hour km hr at which you intend to spray taking into consideration the ground conditions of the area to be sprayed Using the...

Page 21: ...procedure being followed there are several important checks to be carried out prior to starting spraying 1 Inspect the sprayer to ensure there is no damage or wear which could lead to injury further damage or reduce its performance 2 Check all bolts and nuts to make sure they are tight and secure 3 Carry out scheduled lubrication 4 Fit PTO shaft and fit protective cover and chains 5 Make sure the ...

Page 22: ...conds following use This will ensure that no chemical is left in the line prior to the probe being disconnected NOTE This item is intended for the induction of liquid chemicals only To operate the chemical probe 1 Add 20 percent of the tank s volume of clean water to the main spray tank Initially there needs to be a sufficient amount of water in the tank in order for the pump delivery to create th...

Page 23: ...orting the sprayer ie speed regulations oversize signs flashing light etc It is the operator s responsibility to know the relevant regulations Make sure the sprayer is securely hitched to the tractor 3PL Ensure that the boom is securely supported when travelling and that the tail indicator lights on the sprayer are connected via the 7 pin trailer plug if fitted on sprayer CAUTION Take care when re...

Page 24: ...pieces of timber Adjust the top linkage arm until it becomes loose then remove from sprayer Loosen the stabilising chains on the linkage arms then detach arms from the sprayer Disconnect all lines between the sprayer and the tractor i e hydraulic lines foam marker lines etc Remove the PTO shaft from both the sprayer and the tractor NOTE Store the sprayer in a suitable location to prevent freezing ...

Page 25: ...CRUSH HAZARD Keep hands clear of moving parts when carrying out boom fold and unfold sequences CAUTIONS Always ensure that there is adequate room for the boom to open Always ensure that the boom is adequately supported when transporting Boom Height The standard nozzle spacing on Goldacres booms is 500 mm For this spacing the optimum height the boom should be from the object to be sprayed with a 11...

Page 26: ...removed with the bowl cap the valve plunger seats so as to seal off the filter from the supply line Replacing the filter bowl unseats the valve plunger and thus opens the supply line to the filter Suction Filter Cleaning 1 Wear all necessary protective clothing 2 Ensure the pump is turned off 3 Carefully unscrew filter nut and remove bowl 4 Remove screen and clean with a soft brush or compressed a...

Page 27: ...h spraying day Prolonged chemical contact can severely damage seals and diaphragms 9 Regularly check the pump mounting bolts 10 Change the pump oil after the first 50 hours of operation and then after every 300 350 hours Be careful to use the correct oil use SAE 30W40 motor oil and do not overfill Rotate pump manually by hand to remove air locks when filling with oil 11 Do not leave water in pump ...

Page 28: ... to replace the air damper diaphragm as well 1 Flush pump with clean water to remove chemical residue then flush with appropriate decontaminating agent refer to chemical label for decontamination instructions 2 Run pump dry for 15 20 seconds to remove water 3 Remove all air from air damper chamber by pushing in air valve 4 Remove pump from sprayer 5 Remove pump manifolds and pump heads 6 Drain oil...

Page 29: ...5076549 GA5076070 GA5024655 GA5078283 GA5078313 GA5076070 GA5078313 GA5076070 GA5076494 GA5076070 GA5076070 GA5076443 GA5076549 GA5076495 GA5024655 GA5075602 GA5075761 GA5075732 GA5075635 GA5024660 GA5075997 GA5024650 GA5075726 GA5075624 GA5075755 GA5075761 GA5075660 GA5075757 GA5076072 GA5075715 GA5076099 GA5076381 GA5076440 GA5076570 GA5076071 GA5077082 GA5076443 GA5076549 GA5076549 GA5076370 GA...

Page 30: ...076060 GA5076512 GA5075753 GA5076074 GA5076531 GA5076060 GA5076080 GA5076074 GA5076443 GA5076549 GA5076492 GA5076493 GA5075762 GA5075617 GA5075730 GA5078307 GA5075725 GA5075625 GA5075752 GA5075762 GA5075601 GA5076563 GA5076563 GA5076367 GA5076366 GA5076532 GA5076518 GA5076512 GA5076456 GA5078303 GA5076075 GA5075797 GA5076444 GA5076060 GA5075744 GA5075794 GA5078351 GA5076071 GA5077082 GA5076071 GA5...

Page 31: ...ement Check valves in pump Turn the pressure station ball valve to off if the pressure increases on the pump gauge there is a problem with the control valve Measure the flow per minute coming out of one nozzle and check the nozzle chart for the corresponding flow Check the regulator valve is rotating the full 90 degrees when the boom valves are switched off Check tank sump and suction line blockag...

Page 32: ...lator diaphragm has a leak if fitted Replace air accumulator diaphragm Incorrect pump speed Adjust pump speed 400 540 RPM Air leak on suction side of pump Check pump suction for air leaks Pump oil is becoming milky Cracked diaphragm Replace all diaphragms Pump oil is becoming black or dark grey Pump is overheating Check pump speed and oil level Pump is noisy Low oil level Refill or replace oil Dam...

Page 33: ...al joints PTO shaft is too long Shorten PTO shaft Pump housing or mountings cracked PTO shaft not sliding freely or incorrect length Check PTO shaft length and lubricate Repair mountings Extreme cold weather can cause liquid in the pump to freeze and expand Replace damaged housing and drain fluid from pump when storing in very cold conditions ...

Page 34: ...ressure 3 Engage the trigger on the spray lance to start spraying 4 Adjust the nozzle pattern as required by rotating the nozzle in the appropriate direction as required 5 Use a consistent speed or swath pattern to ensure even coverage of the target or adjust the method of application according to your target Agitation Agitation should take place when filling or through another method as deemed su...

Page 35: ...or Model 30L 5A CPB22136 Inlet Body Brass For Model B30L 6 GA5077442 Stem Sub Assembly Brass and Type 302 SS 7 GA5077376 Cup Packing Buna N 7A GA5077377 Cup Packing Viton 8 GA5077421 Gasket Brass 9 GA5077420 Packing Screw Brass 10 GA5077588 Stem Nut SS 11 GA5077589 Trigger Stop Spring Type 302 SS 12 CP7622 302SS 6 Burr Type 302 SS 13 GA5077407 Roll Pin Type 420 SS 14 GA5077427 Roll Pin Type 420 SS...

Page 36: ...p No Performance Liquid Pressure bar 1 5 2 3 4 A B A B A B A B GA8100370 Standard Capacity l min 0 79 2 61 0 98 3 18 1 14 3 67 1 40 4 54 Spray angle º 71 75 77 78 Max throw m 1 2 11 6 1 2 12 8 1 2 13 3 1 2 13 0 GA8100377 Capacity l min 0 98 3 14 1 21 3 79 1 40 4 54 1 70 5 30 Spray angle º 71 75 78 79 Max throw m 1 2 11 7 1 40 13 0 1 5 13 6 1 5 13 2 GA8100371 Capacity l min 1 17 3 71 1 40 4 54 1 63...

Page 37: ...ket leaving hoses connected wrap in cardboard and place in rear of frame under the tank Undo the bolts holding the controller wrap with bubble wrap and place with hoses connected inside the frame next to the pump Place in the accessory box Operator s manual Pump manual Hose reel manual Gun manual Spare controller tap and barb Current marketing material Wrap complete item with shrink wrap 1 2 3 F E...

Page 38: ...ER TITLE MATERIAL DRAWN BY GA4907155 3PL 600L WORK READY NO BOOM JAMES PERKS NEALHARVEY MATERIAL NOT SPECIFIED MODEL EDITED BY 10 12 2014 THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT DRAWING EDITED BY 26 03 2019 REV 06 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES SHEET 1 3 MORANG CR MITCHELL PARK VICTORIA 3355 AUSTRALI...

Page 39: ...8 J ROW A3 SHEET 1 OF 5 DRAWING NUMBER TITLE MATERIAL DRAWN BY GA4907160 3PL 800L WORK READY NO BOOM JAMES PERKS NEALHARVEY MATERIAL NOT SPECIFIED MODEL EDITED BY 11 12 2014 THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT DRAWING EDITED BY 26 03 2019 REV 06 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES SHEET 1 3 MORANG CR ...

Page 40: ... PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES DEBURR AND SHARP EDG 262 98 KG UNLESS OTHERWISE SPECIFIED 0 1 ANGULAR 0 50 0 0 0 5 0 00 0 25 A B C D E F 6 6 5 5 4 4 3 3 Pos Part No Description Qty 1 GA4906615 Tank Assembly 1000L 3PL 1 2 GA4908085 3 Point Linkage Sprayer Frame 1000L 1 3 GA4900714 PTO shaft Series 2 860 mm with quic...

Page 41: ...9 DRAWING CHECKED BY KG DO NOT SCALE DRAWING UNLESS OTHERWISE SPECIFIED 0 1 ANGULAR 0 50 0 0 0 5 0 00 0 25 A B C D E F 4 4 3 3 2 2 1 1 Pos Part No Description Qty 1 GA5071255 Tank 450L with lid 23L hand wash tank Bare 1 GA5071260 Tank 600L with lid 23L hand wash tank Bare 1 GA5071265 Tank 800L with lid 23L hand wash tank Bare 1 GA5071270 Tank 1000L with lid 23L hand wash tank Bare 1 2 GA5071275 Ta...

Page 42: ...0 GA5069815 Screw Countersunk Phillips M4 x 20 ZP 8 11 GA5020295 Valve Ball 12mm 1 2 male female Lever handle Brass 1 12 GA5077704 Hose barb Elbow 90 degree 1 2 male thread x 3 4 hose 1 13 HOS12WSIGHT Hose 12mm Clear Wire reinforced 1 14 GA5000469 Hose clamp 1 2 SS 2 15 GA5077708 Hose barb Elbow 90 degree 1 2 male thread x 1 2 hose 2 Tank Assembly 450 1000L ...

Page 43: ... Implement Pin Cat 2 2 8 GA5003783 End cap Plastic Black Insert RHS 50 x 50 0 8 2 5mm wall 2 9 GA5071885 Tube Insert 75 x 50 x 1 6 4 Rectangular Plastic Black 2 10 GA5000903 Bolt M16 x 25 GR8 8 ZP 2 THIS OF G UN DIM UN 0 0 0 0 00 F E D C B A 1 1 2 2 3 3 8 9 10 REVISIONS REV DESCRIPTION DATE INITIAL ECN 06 Updated as per PSR 2691 per Ballarat test job 18 01 2019 JW A3 SHEET 2 OF 5 DRAWING NUMBER TI...

Page 44: ...2 10 GA5071885 End cap Plastic Black Insert RHS 75 x 50 2 5 4 5mm wall 2 11 GA5071830 T Bolt M12 130mm Long 90mm Wide 2 12 GA5000577 Washer 12mm Flat SS HD 2 13 GA5012461 Nut M12 Nyloc ZP 2 14 GA5007197 Clip R type 4 mm ZP S12 1 15 GA5016789 Top Link Pin Dual Cat 1 16 GA5072730 Lynch Pin Cat 2 28 5mm Dia 140 mm Long 2 11 12 13 14 16 3 4 5 9 6 1 15 2 10 7 8 ITEM N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1...

Page 45: ...needle valve pickup tube GA5023111 Solenoid suit Ezi mate Foam Marker GA5023113 Cap Assembly for Ezimate foam marker 1 GA5006111 Bolt M10 x 35 ZP GR8 8 6 2 GA5000117 Washer 10mm Flat SS HD 12 3 GA5000141 Nut M10 Nyloc ZP 6 4 GA4401530 Plate Foam marker tank mount 1 NOTE 1000L frame shown 1 2 2 3 1 2 2 3 1 2 2 3 4 ITEM M THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT ...

Page 46: ...17 Washer 10mm Flat SS HD 16 5 GA5000141 Nut M10 Nyloc ZP 8 3 4 4 5 1 2 ITEM NO PART NUMBER DESCRIPTION QTY 1 GA5072535 Pressed step tread bolt in 370mm wide painted 1 2 GA4508495 Plate Step Bracket 600L and 800L Frame 3 Point Linkage 2014 2 3 GA5065455 Bolt M10 x 30 GR8 8 ZP 8 4 GA5000117 Washer 10mm Flat SS HD 16 5 GA5000141 Nut M10 Nyloc ZP 8 TH OF U DIM U 0 0 0 0 00 D C B A 1 2 3 ...

Page 47: ...GA5003645 5 16 x 1 1 4 Flat washer SS 1 IT THIS DRAW OF GOLDAC SUB UNLESS DIMENSIO UNLESS 0 1 0 0 0 0 00 0 A B C D E F 6 6 5 5 4 4 Pos Part No Description Qty 1 GA5066080 Hose reel 30m 3 8 hose manual rewind 1 2 GA5006161 Bolt M10 x 25 GR8 8 ZP 4 3 GA5000117 Washer 10mm Flat SS HD 8 4 GA5000141 Nut M10 Nyloc ZP 4 5 GA4900546 Gunjet AA30 adjustable nozzle 1 2 Hose Barb 1 GA5020875 Hose barb 1 4 mal...

Page 48: ...ITED BY 5 12 2014 THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT DRAWING EDITED BY 18 03 2019 REV 05 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES SHEET 1 3 MORANG CR MITCHELL PARK VICTORIA 3355 AUSTRALIA PH 03 5342 6399 DEBURR AND BREAK SHARP EDGES NEALHARVEY 18 03 2019 DRAWING CHECKED BY 108 59 KG DO NOT SCALE DRAWING U...

Page 49: ... THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT DRAWING EDITED BY 22 03 2019 REV 00 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES SHEET 1 3 MORANG CR MITCHELL PARK VICTORIA 3355 AUSTRALIA PH 03 5342 6399 DEBURR AND BREAK SHARP EDGES NEALHARVEY 22 03 2019 DRAWING CHECKED BY 210 52 KG DO NOT SCALE DRAWING UNLESS OTHERWISE S...

Page 50: ...3 GA5000469 Hose clamp 1 2 SS 6 4 GA5004711 Bolt M8 x 25 GR8 8 ZP 2 5 GA5003643 Washer 8mm Flat SS HD 4 6 GA5004917 Nut M8 Nyloc ZP 2 Pos Part No Description Qty 1 GA2000051 Pressure control valve manual constant 4 way Geoline 1 2 GA5000999 3 4 SS hose clamp 2 3 GA5000469 Hose clamp 1 2 SS 6 4 GA5004711 Bolt M8 x 25 GR8 8 ZP 2 5 GA5003643 Washer 8mm Flat SS HD 4 6 GA5004917 Nut M8 Nyloc ZP 2 ...

Page 51: ...60psi 1 9 GA5066940 Socket 1 4 female thread Hex Brass 1 10 GA5045140 Pneumatic fitting Nipple 1 4 BSPT male x 6mm push type Brass 1 3 2 1 Pos Part No Description Qty 1 GA2000051 Pressure control valve manual constant 4 way Geoline 1 2 GA5000999 3 4 SS hose clamp 2 3 GA5000469 Hose clamp 1 2 SS 6 4 GA5004711 Bolt M8 x 25 GR8 8 ZP 2 5 GA5003643 Washer 8mm Flat SS HD 4 6 GA5004917 Nut M8 Nyloc ZP 2 ...

Page 52: ... QTY 1 GA2000085 Main Manual Control Valve Adjustable presure Relief Geoline 1 2 GA2000086 Plumbing Manifold 4 6 Sections Geoline 1 3 GA2000056 Plumbing fitting Hose barb 13mm elbow With oring outlet Geoline 3 4 GA2000060 Plumbing fitting Hose barb 25mm elbow With oring 1 5 GA2000054 Plumbing fitting Hose barb 19mm With oring Bypass Geoline 1 6 GA2000075 Pressure Gauge Rear Mount 25 Bar 1 4 colour...

Page 53: ...24215 Elbow Brass 3 4 Female x 3 4 Female BSPT 1 9 GA5071495 Hose barb brass straight 3 4 male thread x 3 4 hose barb 1 1 2 5 3 6 9 8 7 4 Nuts Bolts and plate come with controller REV ITEM NO PART NUMBER 1 GA2000085 Main Ma 2 GA2000086 3 GA2000056 Plumbing fit 4 GA2000060 Plum 5 GA2000054 Plumbing 6 GA2000075 Pressure Ga 7 GA2000096 Plumbin 8 GA5024215 9 GA5071495 Hose ba MATERIAL DRAWN BY JAMES P...

Page 54: ...DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT DRAWING EDITED BY 28 03 2019 REV UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES SHEET 1 3 MORANG CR MITCHELL PARK VICTORIA 3355 AUSTRALIA PH 03 5342 6399 DEBURR AND BREAK SHARP EDGES NEALHARVEY 28 03 2019 DRAWING CHECKED BY KG DO NOT SCALE DRAWING UNLESS OTHERWISE SPECIFIED 0 1 ANG...

Page 55: ...loc ZP 4 9 GA5000999 3 4 SS hose clamp 1 ITEM N 1 2 3 4 5 6 THIS DRAWING REMA OF GOLDACRES TRAD SUBJECT OF C UNLESS OTHERW DIMENSIONS ARE UNLESS OTHERW 0 1 AN 0 0 0 5 0 00 0 25 A B C D E F 6 6 5 5 4 4 Pos Part No Description Qty 1 GA5078218 Pump Diaphragm type Zeta 70 PTO shaft drive shaft not included 1 2 GA5076400 Cover PTO shaft Black 1 3 GA5014827 Screw Pan head 12g x 1 2 ZP 3 4 GA5002783 Hose...

Page 56: ...LESS O DIMENSION UNLESS O 0 1 0 0 0 5 0 00 0 2 A B C D E F 6 6 5 5 4 4 Pos Part No Description Qty GA3000065 Switch box control 4 boom valves 4V P G RD Geoline GA3000064 Electrical harness 5m extension boom valves Geoline 1 GA2000052 Pressure control valve electric 3 way 3 4 inlet and return 1 2 outlets 1 GA5045140 Pneumatic fitting Nipple 1 4 BSPT male x 6mm push in type Brass 1 2 GA4403145 Suppo...

Page 57: ...SS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES UNTOL DIMENSIONS OPEN DIM 1 00 ANGULAR 0 50 UNLESS OTHERWISE TOLERANCED THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT Surface Finish DRG STANDARD PRACTICE AS 1100 DEBUR ALL EDGES Pos Part No Description Qty 1 GA5011251 U Bolt M12 x 52 x 80 mm Square Top 4 2 GA5012461 Nut M12 Nyloc ZP 8 3 GA5000577 Was...

Page 58: ...Y F GOLDACRES TRADING PTY LTD AND IS BJECT OF COPYRIGHT Surface Finish Approved FINISHED WEIGHT 162 Drawing Checked 29 04 2015 R DRG STANDARD PRACTICE AS 1100 DEBUR ALL EDGES 00 Chemical Probe Assembly Pos Part No Description Qty 1 GA5076005 Cam lever Male plug Suits 1 1 1 4 couplings 1 2 GA5076007 Cam lever 1 female coupler 1 male thread 1 3 GA5078164 Valve Ball 1 female thread inlet outlet Full ...

Page 59: ... 6 GA5077679 O ring 30 x 3mm 1 7 GA5076036 Hose barb Straight 1 1 2 fly nut end x 1 hose barb 1 8 GA5049125 O ring 23 4 x 3 53mm BS213 2 1 2 7 1 1 3 4 8 5 he parts in the kit are used QTY bled 1 1 4 1 4 x 1 2 1 ut 405mm 1 1 1 1 2 1 213 2 3 4 3 5 4 6 7 SCALE 1 5 DWG NO TITLE GOLDAC DO NOT SCALE DRAWING MATERIAL DATE CREATED DRAWN UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS DEBUR ALL ED...

Page 60: ...60 www goldacres com au ...

Reviews: