Installing the Kit
1.
Position the sprayer on a level surface, set the parking
brake, stop the pump, stop the engine, and remove the
key from the starter switch.
2.
Disconnect the negative (-) battery cable from the
battery.
3.
Loosen the worm clamps that secures the manifold
coupler to the agitation valve and section valve
assembly (
).
Figure 1
New flow meter shown
1.
Worm clamp
4.
Transducer clamp
2.
Gasket
5.
Cap
3.
Flow meter
4.
Remove the clamps, gaskets, and manifold coupler
(
Note:
Retain the clamps.
5.
Install the flow meter and 2 flow meter gaskets using
the clamps that you just removed (
).
6.
Remove the transducer clamp, cap, and gasket (
).
7.
Install the flange gasket, cap fitting, and pressure
transducer, securing them using the transducer clamp
that you just removed (
).
Figure 2
1.
Pressure transducer
3.
Cap fitting
2.
Transducer clamp
4.
Flange gasket
8.
Connect the pressure transducer connector from the
machine wire harness to the pressure transducer.
Figure 3
1.
Pressure transducer
connector
2.
Pressure transducer
2