1
2
G034324
200
Figure 22
1.
Increase the desired
distance
2.
Decrease the desired
distance
8.
Ensure that the boom sections are off and press button
2 to begin calibration.
Note:
As you drive the machine, and the speed
calibration progresses, the InfoCenter displays distance
until it reaches the set amount.
Important:
Do not shut off the machine after the
speed calibration completes.
9.
Beginning with the center of the front tire at the “0”
mark, drive the vehicle at approximately 5 to 8 kph (3
to 5 mph) to the other mark, and stop with the center
of the front tire on the mark.
10.
Press button 2 to confirm the distance traveled.
11.
If the calibration is successful, a Calibration Successful
screen appears; press button 5 to exit.
12.
If the calibration is not successful, a Calibration Failed
screen appears with the reasoning behind why the
calibration failed; press button 5 to exit and restart the
calibration.
Manual Calibration Entry
This screen allows you to view and edit the flow calibration
number and the speed calibration number.
Service Screen
To access the Service screen, press button 2 on the Main
Menu screen (
) until you reach Service, and press
button 4 to select Service.
Note:
While spraying, you can view your current flow rate
from the Service screen.
G034305
Figure 23
From the Service screen, select the Hours screen to view the
overall hours of machine, the pump operation hours, and
when the next service is due (
G034304
Figure 24
To reset the Hours screen, press and hold button 3 (
11
Summary of Contents for 41642