Reelmaster 7000−D
Page 6 − 59
Electrical System
Fuel Stop Solenoid (Kubota Diesel Engines Only)
The fuel stop solenoid used on your Reelmaster
7000−D must be energized for the diesel engine to run.
The solenoid is mounted to the injection pump on the en-
gine (Fig. 64).
The Toro Electronic Controller (TEC) monitors the op-
eration of the fuel stop solenoid. The solenoid and its cir-
cuit wiring should be tested as a controller output with
the Diagnostic Display before following the testing pro-
cedure listed below (see Special Tools and Trouble-
shooting in this chapter).
Testing
1. Park machine on a level surface, lower cutting units,
stop engine, apply parking brake and remove key from
ignition switch. Open hood to gain access to engine.
2. Disconnect wire harness connector from fuel stop
solenoid.
NOTE: The fuel stop solenoid may be removed from
the engine or tested in place.
3. If the solenoid is removed from the engine, make
sure that the solenoid plunger moves freely and is free
of dirt, debris and corrosion.
NOTE: Prior to taking small resistance readings with a
digital multimeter, short the test leads together. The me-
ter will display a small resistance value (usually 0.5
ohms or less). This resistance is due to the internal re-
sistance of the meter and test leads. Subtract this value
from the measured value of the component you are test-
ing.
4. Using a digital multimeter (ohms setting), touch one
test lead to the pull coil terminal and the other test lead
to the fuel stop solenoid frame (ground) (Fig. 65). The
resistance of the pull coil should be less than 1 ohm (but
not zero).
5. Using a digital multimeter (ohms setting), touch one
test lead to the hold coil terminal and the other test lead
to the fuel stop solenoid frame (ground) (Fig. 65). The
resistance of the hold coil should be approximately
15 ohms.
6. If either coil resistance is incorrect, replace fuel stop
solenoid.
7. Connect wire harness connector to the fuel stop so-
lenoid.
8. Lower and secure hood.
1. Injection pump
2. Fuel stop solenoid
Figure 64
1
2
1. Fuel stop solenoid
2. Pull coil terminal
3. Hold coil terminal
Figure 65
1
3
2
Electrical
System
Summary of Contents for 03781
Page 1: ...Form No 15214SL Rev D Reelmaster 7000 D Models 03780 A and 03781 Original Instructions EN ...
Page 4: ...NOTES _ ...
Page 6: ...Reelmaster 7000 D This page is intentionally blank ...
Page 8: ...Reelmaster 7000 D This page is intentionally blank ...
Page 10: ...Reelmaster 7000 D This page is intentionally blank ...
Page 16: ...Reelmaster 7000 D Page 1 6 Safety This page is intentionally blank ...
Page 40: ...Reelmaster 7000 D Page 3 18 Yanmar Diesel Engine This page is intentionally left blank ...
Page 70: ...Reelmaster 7000 D Page 4 24 Kubota Diesel Engine This page is intentionally blank ...
Page 80: ...Reelmaster 7000 D Hydraulic System Page 5 10 This page is intentionally blank ...
Page 226: ...Reelmaster 7000 D Hydraulic System Page 5 156 This page is intentionally blank ...
Page 230: ...Reelmaster 7000 D Page 6 4 Electrical System This page is intentionally blank ...
Page 337: ...Reelmaster 7000 D Page 8 3 Chassis This page is intentionally blank Chassis ...
Page 349: ...Reelmaster 7000 D Page 8 15 Chassis This page is intentionally blank Chassis ...
Page 354: ...Reelmaster 7000 D Page 8 20 Chassis This page is intentionally blank ...
Page 440: ...Reelmaster 7000 D Universal Groomer Optional Page 11 20 This page is intentionally left blank ...
Page 459: ...Page 12 19 Reelmaster 7000 D Engine Wire Harness Drawing Model 03780 Yanmar Engin ...
Page 461: ...Page 12 21 Reelmaster 7000 D Engine Wire Harness Drawing Model 03781 Kubota Engine ...
Page 463: ...Page 12 23 Reelmaster 7000 D Seat and Console Wire Harness Drawing Model 03780 30781 ...