Reelmaster 7000−D
Page 6 − 18
Electrical System
NOTE: The initial PIN will be either 1234 or 0000. If the
PIN has been changed and is forgotten, a temporary
PIN can be obtained from your Toro distributor.
The following settings will only be visible if Protect Set-
tings is set to ON and the correct passcode (PIN) has
been entered, or Protect Settings is set to OFF:
Protect Settings: Use the Left/Right button (as indi-
cated by the
at the bottom of the screen) to select
OFF or ON. When Protect Settings is set to OFF, the
remaining settings will be visible and adjustable at all
times. When Protect Settings is set to ON, the re-
maining settings will be visible and adjustable only
after the correct passcode (PIN) has been entered
(see Settings Screen − Protected Menus).
Auto Idle: (Yanmar diesel engines only) When the
engine is running and the machine is in neutral , the
engine will automatically return to the low idle setting
after the set time delay. When the engine is running
and the machine is not in neutral , the engine will au-
tomatically return to the high idle setting after the set
time delay. Use the Left/Right button (as indicated by
the at the bottom of the screen) to select 8, 10, 15,
20 or 30 seconds or the auto idle feature can be set
to OFF.
Blade Count: The blade count setting should match
the number of blades on the cutting unit reels in-
stalled on the machine. The blade count setting is
used by the TEC to manage cutting unit reel speed.
Use the Left/Right button (as indicated by the
at
the bottom of the screen) to select 5, 8 or 11.
The fault
indicator will illuminate and an operator advisor
y
#176 (Reel Speed Changed) will a
ppear on the Info-
Center display to confirm that the change has been
recorded.
Mow Speed: The mow speed setting should match
the current mow speed limiter setting on the machine
(see traction unit. The mow speed setting is used by
the TEC to manage cutting unit reel speed. Press the
Left/Right button (as indicated by the
at the bot-
tom of the screen) then use the Down button to de-
crease or the Left/Right button to increase the mow
speed in 0.5 mph (0.8 kph) increments.
The fault in-
dicator will illuminate and an operator advisor
y #176
(Reel Speed Changed) will a
ppear on the InfoCenter
display to confirm that the change has been record-
ed.
HOC: The HOC (height of cut) setting should match
the current cutting unit HOC. The HOC setting is
used by the TEC to manage cutting unit reel speed.
Press the Left/Right button (as indicated by the
at the bottom of the screen) then use the Down but-
ton to decrease or the Left/Right button to increase
the HOC in 0.063 in. (1.59 mm) increments.
The fault
indicator will illuminate and an operator advisor
y
#176 (Reel Speed Changed) will a
ppear on the Info-
Center display to confirm that the change has been
recorded.
Settings
0.600”
F Reel RPM:
R Reel RPM:
PIN
HOC
1. Front reel RPM
(at TEC set RPM 9)
2. Rear reel RPM
(manually set to 3,
TEC RPM is 9)
3. Left/Right
button
Figure 18
3
SETTINGS SCREEN (F & R REEL RPM)
1
2
F Reel RPM: Initially, the front reel speed is set by the
TEC based on the values entered for blade count,
mow speed and HOC. Front reel RPM can also be
manually adjusted. Use the Left/Right button (as in-
dicated by the at the bottom of the screen) to man-
ually adjust the reel RPM. The fault indicator will
illuminate and an operator advisory #176 (Reel
Speed Changed) will appear on the InfoCenter dis-
play to confirm that the change has been recorded.
The TEC calculated RPM is referenced by when
reel RPM is manually set.
A manual RPM adjustment will remain active until the
blade count, mow speed, or HOC setting is changed.
When one of the cutting unit settings is changed, the
reel RPM will return to the TEC calculated speed.
R Reel RPM: Initially, the rear reel speed is set by the
TEC based on the values entered for blade count,
mow speed and HOC. Rear reel RPM can also be
manually adjusted. Use the Left/Right button (as in-
dicated by the at the bottom of the screen) to man-
ually adjust the reel RPM. The fault indicator will
illuminate and an operator advisory #176 (Reel
Speed Changed) will appear on the InfoCenter dis-
play to confirm that the change has been recorded.
The TEC calculated RPM is referenced by when
reel RPM is manually set.
A manual RPM adjustment will remain active until the
blade count, mow speed, or HOC setting is changed.
When one of the cutting unit settings is changed, the
reel RPM will return to the TEC calculated speed.
Summary of Contents for 03781
Page 1: ...Form No 15214SL Rev D Reelmaster 7000 D Models 03780 A and 03781 Original Instructions EN ...
Page 4: ...NOTES _ ...
Page 6: ...Reelmaster 7000 D This page is intentionally blank ...
Page 8: ...Reelmaster 7000 D This page is intentionally blank ...
Page 10: ...Reelmaster 7000 D This page is intentionally blank ...
Page 16: ...Reelmaster 7000 D Page 1 6 Safety This page is intentionally blank ...
Page 40: ...Reelmaster 7000 D Page 3 18 Yanmar Diesel Engine This page is intentionally left blank ...
Page 70: ...Reelmaster 7000 D Page 4 24 Kubota Diesel Engine This page is intentionally blank ...
Page 80: ...Reelmaster 7000 D Hydraulic System Page 5 10 This page is intentionally blank ...
Page 226: ...Reelmaster 7000 D Hydraulic System Page 5 156 This page is intentionally blank ...
Page 230: ...Reelmaster 7000 D Page 6 4 Electrical System This page is intentionally blank ...
Page 337: ...Reelmaster 7000 D Page 8 3 Chassis This page is intentionally blank Chassis ...
Page 349: ...Reelmaster 7000 D Page 8 15 Chassis This page is intentionally blank Chassis ...
Page 354: ...Reelmaster 7000 D Page 8 20 Chassis This page is intentionally blank ...
Page 440: ...Reelmaster 7000 D Universal Groomer Optional Page 11 20 This page is intentionally left blank ...
Page 459: ...Page 12 19 Reelmaster 7000 D Engine Wire Harness Drawing Model 03780 Yanmar Engin ...
Page 461: ...Page 12 21 Reelmaster 7000 D Engine Wire Harness Drawing Model 03781 Kubota Engine ...
Page 463: ...Page 12 23 Reelmaster 7000 D Seat and Console Wire Harness Drawing Model 03780 30781 ...