![Toptech MultiLoad II DIV-2 Installation Manual Download Page 32](http://html1.mh-extra.com/html/toptech/multiload-ii-div-2/multiload-ii-div-2_installation-manual_1129916032.webp)
23
Figure 4.1
FCM / PCM Connections
Host/TMS Communications
4.2.2
A host/ TMS computer system can be connected to the MultiLoad II/ RCU II in various ways :
-
RS485 4-wire on COM 1
-
RS485 2-wire on COM1
-
RS232 on COM1
-
Ethernet on the ethernet port
4.2.2.1
COM 1 - RS-485 4-wire - Host/TMS Communications
A host/ TMS computer system can be connected to the MultiLoad II/ RCU II via RS485 4-wire on
COM 1.
The TD and RD pairs are swapped at the Host/TMS.
Figure 4.2
RS485 4-Wire, Host to a Single MultiLoad II/ RCU II (recommended)
MultiLoad II/RCUII can be multridropped on the same communication line using a RS485
– 4 Wire
on COM 1 to communicate to a host system.
TDA
TDB
RDA
RDB
RDA
RDB
TDA
TDB
FCM / PCM
#0
MultiLoad II
COM 0
RDA
RDB
TDA
TDB
FCM / PCM
#n
TDA
TDB
RDA
RDB
RDA
RDB
TDA
TDB
Host/TMS
RS485
MultiLoad II/
RCU II #1 COM 1
Host/TMS
RS485
MultiLoad II/ RCU
II #n COM 1
MultiLoad II/ RCU
II COM 1
Summary of Contents for MultiLoad II DIV-2
Page 1: ...MultiLoad II RCU II DIVISION 2 DIV2 Installation Guide Part 6074...
Page 7: ...Hardware Revision 80 9 1 Manual Revision 81 9 2...
Page 20: ...11 2 1 2 4 Side View Figure 2 6 Unit Outline Drawing Side View...
Page 25: ...16 Figure 3 1 Suggested Mounting Position Figure 3 2 Screen Visible Area...
Page 59: ...50 Typical 1 Meter Application Wiring Example IP E Drawing Electrical Wiring Schedule 5 4 14...
Page 64: ...55...
Page 73: ...64...
Page 88: ...79 Chapter8 HardwareRevisionHistory Compatibility Chapter 8...