20
Chapter 4
Data Communications Interface
The MultiLoad II/ RCU II has four (4) communications ports (see Figure3.3), each with a specific
purpose. The following section provides the information required to select and make the wiring
connections to the ports:
Communication
Port
Interface Type
Typical Function
Terminal (Figure 3.3)
Comm. Port 0
RS-485
Internal I/O board /
TB2
FCM I / FCM II / PCM
Communication
Comm. Port 1
RS-232 or RS-485
Host Communication (TMS) /
Printer
TB3 RS-232
TB4 RS-485
Comm. Port 2
RS-232 or RS-485 (2 wire) Ticket Printer/Data Logger
TB5
Ethernet
10/100MBPS
Host Communication (TMS)
J3
Cat 5 (or
higher)Cable
If a service loop is used, the maximum wire length in the service loop should not exceed
3 inches [75mm].
Separate AC and DC wiring by at least 3 inches [75mm]. Do not allow excess wire in the
service loop to overhang printed circuit board.
Default settings in MultiLoad are: COM O
– FCM ; COM 1- HOST , and COM2 – NA.See
the user guide for more details
Only one port may be defined as an FCM, Print or
Alibi Log, otherwise, a ‘Port Usage
Conflict
(s)’ message will display upon re-boot. See the user guide for more details
Chapter
4
Summary of Contents for MultiLoad II DIV-2
Page 1: ...MultiLoad II RCU II DIVISION 2 DIV2 Installation Guide Part 6074...
Page 7: ...Hardware Revision 80 9 1 Manual Revision 81 9 2...
Page 20: ...11 2 1 2 4 Side View Figure 2 6 Unit Outline Drawing Side View...
Page 25: ...16 Figure 3 1 Suggested Mounting Position Figure 3 2 Screen Visible Area...
Page 59: ...50 Typical 1 Meter Application Wiring Example IP E Drawing Electrical Wiring Schedule 5 4 14...
Page 64: ...55...
Page 73: ...64...
Page 88: ...79 Chapter8 HardwareRevisionHistory Compatibility Chapter 8...