Exterior dimensions of the standard MultiLoad II/ RCU II DIV-2 enclosure are shown in Figures 2.2
–
2.6. There is only one mounting orientation possible; reference Figure 2.2 for the MultiLoad II/ RCU II
DIV-2 Mounting Template. The cable entries are located at the bottom of the unit.
Appropriate fasteners must be selected to support the minimum weight of 24 lbs (11 kg). Toptech
offers the following mounting suggestions for three typical surfaces: drywall, wood, or concrete/cinder
block.
Drywall
3.4.1
Insert four fasteners through the corner mounting holes, shown in Figure 2.2. For the fasteners, use #14 x 1
¾” (M6 x 40 mm) Phillips pan head sheet metal screws inserted in #14 (M6) self-tapping nylon anchors.
Place one #
14, 3/8” OD (M6, 10 mm 0D) flat washer under the head of the screw before inserting the screw
into the mounting hole.
Wood
3.4.2
Follow the instructions above for Drywall installation, substituting the
#14 x 1¾” (M6 x 40 mm) wood screws
for the four sheet metal screws. Do not use the self-tapping nylon inserts
.
Concrete or Cinder Block Walls
3.4.3
Follow the instructions above for Drywall installation, substituting the
a 1/4 ” x1 3/4” Tapcon masonry fastener
for the four sheet metal screws. Do not use the self-tapping nylon inserts.
Drill pilot holes for the Tapcons using a 3/16” x 3 ½” masonry drill bit.
Mounting Height Considerations
3.4.4
When mounting the enclosure, be aware of the limitations that the cover places on screen visibility.
Because the display is inset about an inch [25mm] from the surface of Div-2 and SMP units and the
screen is inset an inch-and-one-half [39mm] in the EXL unit, the enclosure should be mounted so that
top of the screen’s visible area is at eye level of the tallest operator. Figure 3.1 shows the visible area
at arm’s length and the distance from the ground to the top mounting hole location for a six-foot [1.8m]
tall user. Figure 3.2 shows the offs
et of the top of the screen’s visible area from the top mounting bolt
and the depth of the screen within the unit.
Summary of Contents for MultiLoad II DIV-2
Page 1: ...MultiLoad II RCU II DIVISION 2 DIV2 Installation Guide Part 6074...
Page 7: ...Hardware Revision 80 9 1 Manual Revision 81 9 2...
Page 20: ...11 2 1 2 4 Side View Figure 2 6 Unit Outline Drawing Side View...
Page 25: ...16 Figure 3 1 Suggested Mounting Position Figure 3 2 Screen Visible Area...
Page 59: ...50 Typical 1 Meter Application Wiring Example IP E Drawing Electrical Wiring Schedule 5 4 14...
Page 64: ...55...
Page 73: ...64...
Page 88: ...79 Chapter8 HardwareRevisionHistory Compatibility Chapter 8...