27
DISABLE SPECIAL FUNCTIONS
instructions for installation
M200
SERVOASSISTED FUNCTION WITH DISABLE USER BUTTON
By connecting the external and internal opening buttons as per the following diagram and correctly setting parameter
113 on the board, the door will enter Servo / Push & GO mode. Setting parameter 113 = 3, the Push & GO function is
activated with safety sensors activated Setting parameter 113 = 2 the Push & GO function is activated with sensors
deactivated it is necessary to activate the LOW ENERGY.
DISABLED USER RESTROOM DOOR FUNCTION (parameter 135= 9)
The system operates following this sequence:
•
When the restroom is free, pressing the ex
-
ternal button (E), the door opens.
• When the door is closed pressing the internal
button (I) the door locks, signaling that the
restroom is occupied.
•
Connect a 24Vdc electric lock on the lock
connection input (8)
•
The outside button of the restroom (E) should
be connected to the external radar input (22).
•
The internal button of the restroom (I) should
be connected to internal radar input (18)
•
On the output of the air curtain (6) a flush
command might be connected.
• Connected to a display that shows “occu-
pied” or “free” to the output on the disabled
user restroom display (5)
•
Set an appropriate auto-closing time: param
-
eter 122, sufficiently long to allow a disabled
user to enter the restroom.
•
Set the parameter 104=0
1 9 17 25
6 14 22 30
2 10 18 26
3 11 19 27
8 16 24 32
7 15 23 31
4 12 20 28
5 13 21 29
occupato
5
6
18
22
E
I
8
20