instructions for installation
ELECTRICAL CONNECTIONS
BEFORE MAKING THE ELECTRICAL CONNECTION OF THE AUTOMATION, CHECK THAT:
• The main power supply connected to the automation must comply with the requisites contemplated by the legislation
in force in the country of installation, and must have the technical characteristics indicated in tab.2- cap.2.5 and on the
rating plate, as well as the “CE” seal of approval.
•
Electrical connection of the automation must be made exclusively by skilled, qualified technical personnel in possession
of the professional requisites contemplated by the legislation in force in the country of installation, who shall issue the
client a declaration of conformity of the connection and/or installation made.
•
The main power supply connected to the automation shall be provided with an omnipolar magneto-thermal differential
30mA switch with aperture of at least 3 mm between the contacts. This device shall be installed in the power supply sy
tem in accordance with the requisites contemplated in the legislation in force in the country of installation.
• The power line must be protected against earth leakage and the installation shall provide a grounding line longer than
the power line so that if pulled, the ground line is the last to go taut.
• Before making electrical connections make sure there is no power on the mains.
• The recommended power cables are as follows: H05VV-F 3X0.75, H05RN-F 3X0.75, self-extinguishing types for electrical
connections. For wiring of the analogue selector we recommend using a multipole 8 x 0.5 type LI-YY.
• The installer shall take care to secure the power cable stably inside the automation. The cable will be inserted in the main
entry hole of the automation with its sheath.
• Limit stripping of the primary sheath of the cable to the distance necessary for connection to the terminal
• Before making the electrical connection of the automation, check that the power cable is undamaged.
• The hole in the substratum for passage of the power cable shall be made without rough or sharp edges or points that
could damage the cable.
• Connection to the power mains in the portion outside the automation shall be made on an independent channel, separate
from the connections to the control and safety devices.
• Any type of electrical material (plug, cable, clamps, etc.) used for connection must be suitable for the purpose, marked
“CE” and must comply with the requisites envisaged by the legislation in force in the country of installation. For wiring,
use cable with double insulation up to the immediate vicinity of the connectors.
• Whenever the operator is powered up with battery only, and whatever is the operation mode set, to perform a complete
power off, press and hold for 5 seconds near/reset button.
POWER SUPPLY