MANUALE DI INSTALLAZIONE 

AUTOMAZIONE

Max capacity 250 Kg

M200

Summary of Contents for M200

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE M200 STANDARD INSTALLATION ORIGINAL INSTRUCTIONS COD 0P5711 VER 00 REV 07 20 ...

Page 2: ...ORMATION and SAFETY PAG 4 PRELIMINARY OPERATIONS PAG 5 ARTICULATED ARM INSTALLATION PAG 6 SLIDING ARM INSTALLATION PAG 8 SLIDING ELBOW ARM INSTALLATION PAG 10 ELECTRICAL CONNECTIONS PAG 12 FIRST STARTUP SELF LEARNING PAG 17 DOUBLE LEAF INSTALLATION PAG 18 ERRORS LIST PAG 20 21 ...

Page 3: ...d configuration with normal arm The feature of the automation facilitates the installation process The opening and closing movement of the door is regulated by the software of the electronic circuit board which manages the application of the forces and the continuity of movement in the different configurations The electronic board is a microprocessor type with keys directly on it for regu lation o...

Page 4: ...vely by qualified technical personnel in possession of the professional requisites contemplated by the legislation in force in the country of installation The installer must be able to install the automation and start it and to operate in the presence of electrical power inside electric cabinets and shunt boxes He must be quali fied to make all the necessary adjustments of an electrical and mechan...

Page 5: ...he wing is rigid and sturdy The hinges are adequate and in good conditions The door has a mechanical stop in opening not supplied see Figure Ref 1 3 cm further than the maximum desired opening position The door closes firmly and smoothly The power supply cables and the control cables for the sensors and or related accesso ries have been prepared If necessary in case of installation with rotation a...

Page 6: ...late to the lower edge of the frame and the axis of rotation of the door 1 1 2 3 4 lower end of the frame fixing plate lower end of the frame fixing plate The automation must be fixed on the side of the wall which is opposite to the hinges The distance A varies according to the type of the Axls extension used See the table The automation must be fixed on the side of the wall which is opposite to t...

Page 7: ... figure 2 If the application required insert the axle extension ARM ADJUSTMENT 1 Fix the arm bracket to the door with two appropriate screws in the holes previ ously drilled 2 Loosen the two screws for the arm length adjustment 3 Make sure the door is closed position the extendable lever of the arm at a 90 angle from the door adjust the arm length and tighten the two adjustment screws ARM FITTING ...

Page 8: ...ing with right hinge Pay attention to the orientation of the fixing plate to the door edge and the axis of rotation of the door 1 1 2 3 4 door edge fixing plate door edge fixing plate automation external dimensions automation external dimensions standard 3S1100 3S1101 3S1102 A mm 55 80 105 130 3S1020 B mm 0 30 standard 3S1100 3S1101 3S1102 A mm 55 80 105 130 3S1020 B mm 0 30 The automation must be...

Page 9: ...runner then fit the guide in the runner taking care to leave the two larger holes on the outside SLIDING GUIDE FITTING 1 Fix the sliding guide with two appropriate screws in the holes previously drilled 2 Fit the caps in the front holes 3 Fit the lateral caps of the guide ARM FITTING 1 Apply the supplied glue to the upper part on the outer conical surface of the pin making a circumference all arou...

Page 10: ...he orientation of the fixing plate to the door edge and the axis of rotation of the door 1 1 2 3 4 The automation must be fixed on the side of the hinges The distance A varies according to the type of the Axls exten sion used See the table door edge fixing plate door edge fixing plate automation external dimensions automation external dimensions C C 3S1030 3S1031 B mm 0 100 101 200 C mm 107 5 277 ...

Page 11: ...elbow arm 3 Grease the runner then fit the guide in the runner taking care to leave the two larger holes on the outside SLIDING GUIDE FITTING 1 Fix the sliding guide with two appropriate screws in the holes previously drilled 2 Fit the caps in the front holes 3 Fit the lateral caps of the guide ARM FITTING 1 Apply the supplied glue to the upper part on the outer conical surface of the pin making a...

Page 12: ...efore making electrical connections make sure there is no power on the mains The recommended power cables are as follows H05VV F 3X0 75 H05RN F 3X0 75 self extinguishing types for electrical connections For wiring of the analogue selector we recommend using a multipole 8 x 0 5 type LI YY The installer shall take care to secure the power cable stably inside the automation The cable will be inserted...

Page 13: ...00 ELECTRICAL CONNECTIONS PRE WIRED ELECTRIC CONNECTIONS POWER SUPPLY CIRCUIT 1 ON OFF Switch 2 Function selector 3 Led signal Near 4 Battery 5 Electronic board 6 Motor 7 Encoder 8 Transformer 9 Filter 10 Fuse 11 Power supply connection ...

Page 14: ...RE PRESENT CONNECTION OF IS6 TOPP SAFETY SENSOR HOTRON SSS 5 CONNECTION OF OPTEX SAFETY SENSORS OPTEX AO EDGE T OPENING SAFETY SENSOR CLOSING SAFETY SENSOR Modify these values if you want to reduce or enlarge the de tection area see sensor manual Configure as in figure OPENING SAFETY SENSOR CLOSING SAFETY SENSOR ...

Page 15: ...UPPLEMENTARY SAFETY SENSOR HOTRON SSS 5 CONNECTION OF OPTEX SUPPLEMENTARY SAFETY SENSORS OPTEX AO EDGE T SUPPLEMENTARY OPENING SAFETY SENSOR SUPPLEMENTARY CLOSING SAFETY SENSOR Modify these values if you want to reduce or enlarge the detection area see sensor manual Configure as in figure SUPPLEMENTARY OPENING SAFETY SENSOR SUPPLEMENTARY CLOSING SAFETY SENSOR ...

Page 16: ...M ATTIVAZIONE N O COM RADAR INTERNO ATTIVAZIONE 24 23 18 20 20 22 23 24 RADAR ESTERNO ATTIVAZIONE Parametro D 0 oppure D 2 D 4 Elettroserratura ACTIVATION SENSORS CONNECTION IF THEY ARE PRESENT CONNECTION OF ELECTRIC LOCK If the electric lock is present configure the parameters 127 132 133 See page 21 for programming iINTERNAL ACTIVATION SENSOR EXTERNAL ACTIVATION SENSOR ELECTRIC LOCK ...

Page 17: ...successfully the detected sensors are shown on the display as in the example in the side to allow the installer to verify the correct acquisition of the sensors If an error occurs check the error map on page 20 In Full Energy it is essential that at least the two main safety sensors are installed the lack of even one of the sensors causes an error The safety sensors are monitored and therefore mus...

Page 18: ...s are installed cor rectly and the door leaves are in CLOSE position Set parameter as 1 on MASTER and 2 on SLAVE Set independently for each wing the pa rameters 101 102 103 104 105 related to weight width wall depth sensors logic for activation and safety as shown in page 21 Following the instructions on page 17 per form the learning process of the MASTER door leaf first and the SLAVE door leaf la...

Page 19: ...ry 24 months replace the emergency battery system remember to disconnect the power The duration of the battery back is affected by the environmental and functional conditions of the automation ACCESSORIES AND PARTS ON REQUEST Always use original spare parts and accessories Non original parts could endanger safe and efficient operation of the automation Original spare parts and accessories must be ...

Page 20: ...M200 20 instructions for installation LIST OF ERROR MESSAGES AND NOTICES ...

Page 21: ...y can be enter based on the door dimensions parameter setting MANDATORY PARAMETER 0 1 2 3 4 5 6 7 8 9 25 KG 50 KG 75 KG 100 KG 125 KG 150 KG 175 KG 200 KG 225 KG 250 KG 102 DOOR DIMENSIONS Only weights that the automation can manages safely can be enter based on the door weight parameter setting MANDATORY PARAMETER 0 1 2 3 4 5 6 7 8 9 500 mm 600 mm 700 mm 800 mm 900 mm 1000 mm 1150 mm 1300 mm 1450...

Page 22: ...inside to outside Enabled from outside to inside 107 FIRE ALLARM INPUT LOGIC A command on this input causes the door to open even when it is closing When this command is disabled the automation returns to the previous state 0 1 NO NC 108 INPUT OPEN A command on this input causes opening of the door even when it is closing 0 1 NO NC 109 HARD RESET Resets to the native state Serves to return the mac...

Page 23: ...eting an opening and closing cycle at low speed with safety sensors disabled a failure to comlete this sycle lights up an error it performs a NEAR at low speed till an opening and closing cycle is successfully completed with safety sensors enabled 118 FINAL TRACTION Serves to regulate the closing force and guarantee the closing of the door Adjustable from 0 to 9 0 1 2 3 4 5 6 7 8 9 Increasing the ...

Page 24: ...ON Regulates the force applied to the obstacle in full energy before stopping 0 1 2 3 4 5 6 7 8 9 0 is the minimum force and 9 is the greatest 125 ANTIWIND FORCE WITH CLOSED DOOR Force applied on closed door edge to prevent open ingn case of wind 0 1 2 3 4 5 6 7 8 9 Disabled Increasing the value increases the force 126 WIND RESISTANCE FORCE WITH OPEN DOOR Force applied on open door edge that preve...

Page 25: ...dicates who electronic lock is controlled Values from 5 to 8 s erve for locks that can work with 24V power panel with duty cycle at 50 0 1 2 3 4 5 6 7 8 No lock Lock if powered Lock if not powered Impulsive s electing the parameter with a value different of 0 Bistable One impulse opens and another closes Lock of powered at duty 50 Lock if not powered at duty 50 Impulsive at duty 50 Bistable One im...

Page 26: ...lation ARM REMOVAL Arm removal Extractor cap 1 Isert the extractor cap by screwing it clockwise If not already entered 2 Turn the fastening screw anticlockwise so that it pushes on the extractor cap and removes the arm from its seat ...

Page 27: ... pressing the ex ternal button E the door opens When the door is closed pressing the internal button I the door locks signaling that the restroom is occupied Connect a 24Vdc electric lock on the lock connection input 8 The outside button of the restroom E should be connected to the external radar input 22 The internal button of the restroom I should be connected to internal radar input 18 On the o...

Page 28: ...M200 28 instructions for installation EC DECLARATION OF INCORPORATION ...

Page 29: ...29 instructions for installation M200 ...

Page 30: ...M200 30 instructions for installation ...

Page 31: ...31 instructions for installation M200 ...

Page 32: ...o soggetta a direzione e coordinamento di 2 Plus 3 Holding S p a via Galvani 59 36066 Sandrigo VI tel 39 0444 656700 fax 39 0444 656701 www topp it info topp it MANUALE DI INSTALLAZIONE AUTOMAZIONE Max capacity 250 Kg M200 ...

Reviews: