CONFIGURATION OF AUTOMATION PARAMETERS
ref.
display
parameter description
val.
*default*
value description
114
MAINTENANCE
*0*
1
2
Resets everything
Resets only cycle counter
Reset only distance
115
ANGLE OF INHIBITION OF
OBSTACLE SAFETY SENSOR
Blind spot of safety sensor on opening (hinge side):
indicates the degrees from limit switch in opening in
which the sensor is disabled. Increasing the value
increases the area of the blind spot.
*0*
1
2
3
4
5
6
7
8
9
0°
3°
6°
9°
12°
15°
18°
21°
24°
27°
116
AUTOMATIC LEARNING OF PARAMETER
115
When enabled it permits automatic learning of
parameter 115.
0
*1*
Disabled
Enabled
117
NEAR
function
*0*
1
2
it performs a NEAR looking for the door closed position
it performs a NEAR completing an opening and closing cycle
at low speed with safety sensors disabled.a failure to comlete
this sycle lights up an error
it performs a NEAR at low speed till an opening and closing
cycle is successfully completed with safety sensors enabled.
118
FINAL TRACTION
Serves to regulate the closing force and guarantee
the closing of the door. Adjustable from 0 to 9.
0
*1*
2
3
4
5
6
7
8
9
Increasing the value increases the force.
119
OPEN SPEED
in full energy mode.
0
1
2
3
4
*5*
6
7
8
9
Increasing the value increases the speed during the
opening maneuver.
120
CLOSING SPEED
in full energy mode
0
1
2
3
4
*5*
6
7
8
9
Closing speed adjustment in full energy mode.
Increasing the value increases the speed during
closure.
121
RECLOSURE TIME KEY DEVICE
Indicates the time for which the door remains open
after the end of the impulse given with the key
device. Adjustable from 0 to 60 sec.
0
*1*
2
3
4
5
6
7
8
9
0 s
5 s
10 s
15 s
20 s
25 s
30 s
40 s
50 s
60 s