Power Mode 2. By AC electricity and back-up batteries, only use the AC
electricity to charge the batteries
If the AC electricity failure happens rarely (less than 8 hours per day), then you can use minimum 5AH
2*12VDC batteries as back-up power source in case of AC power failure. In this situation, you can connect the
UPS-01 to the control box refer to step 1 in this chapter. And then you can connect 2 PCS 12VDC batteries in
series and then connect it to the UPS-01 power supply.
Power Mode 3. Use the batteries as the power source, only use the solar
panel to charge the batteries
If the AC electricity is not available, then you can choose the batteries as the power source and use the solar
panel to charge the batteries. The capacity of the batteries should be at least 12AH and the power of the solar
panel should be at least 20W in this situation. The gate opener can run for 10 cycles per day without connecting
any other accessories except pushbutton & alarm lamp if the local average sunshine time is more than 6 hours
per day. The power of the solar panel and the capacity of the batteries should be enlarged if the local average
sunshine time is less than 6 hours per day or using one of the accessories (photocell, external receiver, exit