23
3. UPS-01 Power Supply
Before connecting this item, please refer to the chapter of
―Connection of the Power Supply‖
.
4. Battery
(
not included) & solar panel (optional, ONLY included in A3132/A5132/A8132 S)
Please connect them following the chapter of
―Connection of the Power Supply‖
.
5. Warning Light (Included in some models, refers to the actual package)
The red wire of the warning light should be inserted into
LAMP (#25)
terminal, the white wire into the
LAMP-
(#26)
.
6. Photocell Beam System (PBS)
(Included in some models, refers to the actual package)
Use a 2-core cable to connect the
―+ ~‖
terminal of the
photocell’s emitter to the “
+24
” (#1) terminal, the
―- ~‖
terminal to the
“
GND
” (#3) terminal. Also the
―+ ~‖
and
―- ~‖
terminals of the
photocell’s receiver should be
connected to the
“
+24
” and “
GND
” terminals in parallel.
Use another 2-core cable to connect the
―NC‖
terminal of the receiver to the
“
PHOTO
” (#2) terminal, the
―COM‖
terminal to the
“
GND
” (#3) terminal.
7. Push Button (optional)
The push button should be wired to the “#4 and “#5” terminals. No matter the polarity. The gate operator works
alternately by pressing the button (open-stop-close-stop-open).
8. Electric Lock (optional)
A lock plus board is required to connect the electric lock to the control board. The 2 wires of J1 of lock plus
should be wired to the
“13#” and “14#” terminal of the control board. No matter the polarity. Red wire of J2
should be wired to the 11# terminal and yellow wire of J2 should be wired to the 12# terminal. Red wire of J3
should be connected to the red wire of electric lock and also the yellow wire of J3 should be connected to the
yellow wire of electric lock.
NOTE: If you use the AC electricity as the power source and intend to use the electric lock, the open
delay time of the 2 actuators should be more than 4S.
9. Exit Wand (optional)
The
BLACK
wire of the exit wand
should be connected into the “#5” terminal.
The
BLUE
wire of the exit wand
should be connected into the “#6” terminal.
The
RED
wire of the exit wand
should be connected into the “#11” terminal.
The
GREEN
wire of the exit wand
should be connected into the “#12” terminal.
The sensitivity adjustment board should be wired to the
GREEN
wire and the
YELLOW
wire of the wand. No
matter the polarity.
10. Wired Keypad (24VDC)(optional)
The
RED
wire of the wired keypad should be connected into the “#11” terminal.
The
BLACK
wire of the wired keypad should be connected into the “#5” terminal.
The
PURPLE
wire of the wired key
pad should be connected into the “#5” terminal.
The
BLUE
wire of the wired keypad should be connected into the “#4” terminal.
Summary of Contents for A3132
Page 6: ...3 A3132 Parts List...
Page 7: ...4 A5132 A8132 Parts List...