Operating Procedures
Operation
Display
1. After inputting the ground
height of backsight point,
the screen will display “Bk1
(backsight). If the previous
step is “Start Leveling”,
screen will display
BM#(Benchmark number).
2. Sight at the staff which is
on the backsight point (Bk1).
3. Press [MEAS] key.
Example: If it measures 3
times, after surveying, the
average value will be
displayed for M seconds
※
1).
4. When it is in continuous
measuring mode, press [ESC]
to display the last measuring
data for M seconds.
5. Then the screen will
display “Fr1” and the
foresight point name will
increase or descend
automatically. Now press
[ESC] can modify the point
name. After that, collimate
the staff in the foresight
Sight at Bk 1
[MEAS]
In continuous
measuring mode
[ESC]
Sight at Fr1
[MEAS]
Level BFFB
B1Rod:0.8259m
B1Dist: 3.914m
N:3 >>>>>>>>>
Level BFFB
Bk1
BM#:B01
Press [MEAS] to meas
Level BFFB
F
Bk1
BM#:B01
>>>>>>>>>
Level BFFB 1/2
B1Rod Ave:0.8259m
B1Dist Ave: 3.914m
N:3
δ
:0.00mm
Level BFFB
Fr1
PN :P01
Press [MEAS] to meas