103
11. Collimate the staff in point
b and press [MEAS] (As shown
in the figure 2), meanwhile,
take measurement and the
screen will display Bb.
12.Display the adjusting value.
If user wants to continue
adjustment, press [ENT].
13. Press [ENT] to display the
rod reading of point b.
14. Rotate the rod reading of
point b and remove the
eyepiece cover 1, use adjusting
pin to rotate the crosshair
adjusting screw 2 under the
eyepiece.
Note: This adjustment must be
carried out by the professional
person.
15. Collimate the staff and read
the value manually. Move the
crosshair up and down until
the horizontal line is consistent
with the correct reading.
[MEAS]
[MEAS]
[ENT]
Adjust A
Point:B Rod:a
a
←
----B b
Press [MEAS] to meas
Adjust A
Point:B Rod:a
Ba Rod:1.0567m
N:3
δ
:0.02mm
Adjust A
Point:B Rod:b
a B----
→
b
Press [MEAS] to meas
Adjust A
Point:B Rod:b
Bb Rod:1.0567m
N:3
δ
:0.02mm
Adjust A
Adjusting value
+0.0000m(+0.1”)
Save[ENT] No[ESC]
Adjust
Method A
Adjust Crosshair?
Yes:[ENT] No:[ESC]