![Tonghui Electronics TH9201 Series Operation Manual Download Page 55](http://html1.mh-extra.com/html/tonghui-electronics/th9201-series/th9201-series_operation-manual_1126463055.webp)
◇
55
SOUR:SAFE:STEP <sn>:DC:TIME:TEST <time>
Query message:
SOUR:SAFE:STEP <sn>:DC:TIME:TEST?
--Program data
<sn>:
Data format: Integer
Set value: 1~49
Resolution: 1
Unit:
--Program data
<time>:
Data format: float
Set value: 0~999.9 (0 is OFF)
Resolution: 0.1
Unit: s
--
Example:
To set the TEST time for step 1 to 1,
:SOUR:SAFE:STEP 1:DC:TIME:TEST 1.
--
Example:
:SOUR:SAFE:STEP 1:DC:TIME:TEST?
If the current TEST time for step 1 is 1,
1 is returned .
:SOUR:SAFE:STEP:DC:TIME:DWEL
Sets the WAIT time for DCW test.
Also inquires about the WAIT time.
--Syntax
:
Command message:
SOUR:SAFE:STEP <sn>:DC:TIME:DWEL <time>
Query message:
SOUR:SAFE:STEP <sn>:DC:TIME:DWEL?
--Program data
<sn>:
Data format: Integer
Set value: 1~49
Resolution: 1
Unit:
--Program data
<time>:
Data format: float
Set value: 0~999.9 (0 is OFF)
Resolution: 0.1