![Tonghui Electronics TH9201 Series Operation Manual Download Page 51](http://html1.mh-extra.com/html/tonghui-electronics/th9201-series/th9201-series_operation-manual_1126463051.webp)
◇
51
Resolution: 1
Unit:
--Program data
<volt>:
Data format: float
Set value: 50~6000
Resolution: 1
Unit: V
--
Example:
To set the test voltage for step 1 to 1000,
:SOUR:SAFE:STEP 1:DC:LEV 1000.
--
Example:
:SOUR:SAFE:STEP 1:DC:LEV?
If the current test voltage for step 1 is 1000,
1000 is returned.
:SOURce:SAFEty:STEP:DC:LIMit:LOW
Sets the LOWER current for DCW test.
Also inquires about the LOWER current.
--Syntax
:
Command message:
:SOUR:SAFE:STEP <sn>:DC:LIM:LOW <current>
Query message:
:SOUR:SAFE:STEP <sn>:DC:LIM:LOW?
--Program data
<sn>:
Data format: Integer
Set value: 1~49
Resolution: 1
Unit:
--Program data
<current>:
Data format: float
Set value: 0~10.000E-3 (0 is OFF)
Resolution: 1.000E-6
Unit: A
--
Example:
To set the LOWER current for step 1 to 0.001,
:SOUR:SAFE:STEP 1:DC:LIM:LOW 0.001.
--
Example: