Tolomatic Hardware & Installation Guide:
ACS Drive/Controller
• 6-8 •
6:
S p e c i f i c a t i o n S & W i r i n g
use more than 4 Amps.
Supply power = current x 24V
Example: If 2.3A is needed, 2.3A x 24V = 55.2W.
6.5.4 Suggested Power Supplies
Switching Power Supplies
Power Output
CUI PN: VGS-25-24
25W
CUI PN: VGS-50-24
50W
CUI PN: VGS-75-24
75W
TDK-Lambda PN: LS150-24
150W
Table 6-7: Recommended Switching Power Supplies
linear Regulated Power Supplies
Power Output
Power One PN: HB24-1.2-AG
28W
Power One PN: HN24-3.6-AG
80W
Power One PN: HD24-4.8-AG
115W
Table 6-8: Recommended Linear Regulated Power Supplies
linear Unregulated Power Supplies
Power Output
Acopian PN: U24Y500
120W
Acopian PN: U24Y350
84W
Table 6-9: Recommended Linear Unregulated Power Supplies
Fuses (Slow Blow type)
Bus Fuse: 4A
Logic Power Fuse: 1A
Table 6-10: Fuses