To change setpoints
1)
Push
to enter change mode. Station 1 is then selected.
2)
Push
to select the desired station.
3)
Push
or
to change the value, or
Push
or
to change in a larger increment.
4)
Push
to accept the change (the next station will be selected), or push
to cancel
the change.
5)
Repeat from Step 2 to make changes on other stations.
6)
Push
to exit change mode.
Note:
To bypass a station’s setpoint, change the station’s setpoint % to zero. For example, to
disable reverse alarms for station 4, change the REV-% for station 4 to zero.
To view corner tonnage distribution
1)
Push
or
until the center menu shows
CORNR
.
2)
The peak tonnage values for each channel are shown in the associated corners of the
LCD, with the total displayed in the center.
Summary of Contents for PWi Forging