Load Sensor Connection
Refer to Figure 1.8 for the procedures below to connect tonnage sensors properly:
1)
Power down the unit. Open the door of the PWi Forging enclosure.
2)
Run Load Sensor cables through Conduit Hole #1 (see Figure 1.4), and route cables upward to
the Analog Board.
3)
Prepare the sensor cable for termination as described on page 17.
4)
Remove the four 5-pin Phoenix plugs from the analog board and wire each sensor cable as
described on page 18.
5)
The 5-pin phoenix plugs can then be inserted into the corresponding sockets. The load sensor
cable connections are now complete.
Analog Board
Channel 1
Left Rear Sensor
Channel 2
Right Rear Sensor
Channel 3
Left Front Sensor
Channel 4
Right Front Sensor
Figure 1.8: Sensor Input Locations