47
MAINTENANCE IN COLD CONDITION
For vacuum strainer
1.
Turn the ring nut while holding and pressing
the strainer cup for the vacuum pump, remove
the strainer and strainer cup.
2.
Inject antifreeze (undiluted 50 ml) to the
strainer guide.
3.
After injection, assemble the
strainer and strainer cup by
tightening the ring nut.
・
When installing the strainer,
exercise care so that the O-
ring does not get caught in,
and tighten the ring nut
securely. If the ring nut is not
tightened completely, vacuum
leak may occur.
・
Pay attention to the protrusion of
the O-ring while installing the O-
ring. Install it correctly.
Otherwise, a vacuum leak may
occur.
・
When installing the strainer,
tighten the ring nut while
pressing the cup with your palm.
Discharge valve
Fill the inside of the discharge valve with
antifreeze
using a long nozzle containing
antifreeze liquid.
12
NOTE
CAUTION
Ring nut
Strainer
cup
Antifreeze
50 ml
Strainer
guide
O-ring
Strainer