Chapter 9: CONNECTIONS
7. cABlE DISTANcE BETWEEN cOmPONENTS
9-35
7. CABLE DISTANCE BETWEEN COMPONENTS
7.1. VX-2000 to Remote Microphone Cable Distance
The cable distance between remote microphones (rm-200X or rm-200Xf) is determined by the specifications
of the lONWOrKS' Twisted Pair free Topology Network (assuming cat. 5 STP cable is used).
[Connection example and total cable distance]
VX-2000
VX-200XR
VX-200XR
VX-200XR
VX-200XR
RM
RM
RM
RM
RM
RM
RM
RM
a
b
c
d
e
f
g
h
Transceiver
The maximum total cable length between all connected remote microphones and the VX-200Xr is 450 m.
However, the maximum length between individual components within the system is 250 m.
a + b + c + d + e + f + g + h
450 m
(a, b, c, d, e, f, g, and h: Individual connections
250 m)
Tips
cable distances can be increased by changing the cable type.
cable Type
Total cable Distance
maximum cable Distance Between components
Belden 85102
500 m
500 m
Belden 8471
500 m
450 m
level IV, 22AWG
500 m
400 m
Jy (St) y 2 x 2 x 0.8
500 m
320 m
cat. 5 STP
450 m
250 m
Summary of Contents for VP-2241
Page 12: ...Chapter 1 Note...
Page 17: ...Chapter 2 ProduCt desCriPtioNs...
Page 41: ...3 1 Chapter 3 system oPeratioN outliNe...
Page 56: ...Chapter 4 FuNCtioNs...
Page 73: ...Chapter 5 oPeratioN...
Page 112: ...Chapter 6 FloWCHart From system setuP to oPeratioN...
Page 116: ...Chapter 7 PC soFtWare oFFliNe settiNGs...
Page 179: ...Chapter 8 iNstallatioN aNd settiNG ProCedures HardWare...
Page 223: ...Chapter 9 CoNNeCtioNs...
Page 266: ...Chapter 10 PC oNliNe CHeCKs aNd adJustmeNts...
Page 282: ...Chapter 11 otHer PC soFtWare FuNCtioNs...
Page 292: ...Chapter 12 aPPeNdiX...
Page 298: ...Chapter 13 sPeCiFiCatioNs...
Page 328: ...url http www toa jp 201409...