k. Remote Settings Page (Mainframe)
1
4
5
L
In MATRIX Mode: The LOAD BANK/EVENT setting
cannot be accessed from this page. When an EVENT
is programmed to be activated by a ZM controller in
the EVENT Settings Page, that controller’s status will
then be indicated in the Remote Settings Page.
3
2
The Remote Settings Page allows programming for the controllers connected to the
REMOTE 1 & REMOTE 2, 2-wire connections on the 9000 mainframe’s rear panel. Two
controllers of any type listed may be assigned.
1. TYPE.
Selects the controller type from the drop-down list (see “Controlling the 9000” for
more details on the controllers):
•
Volume
-When a 10kOhm variable resistance potentiometer is used for volume
control.
•
ZM-9001:
When a ZM-9001 Zone Manager is used
•
ZM-9002:
When a ZM-9002 Zone Manager us used
2.
If a ZM 9001 or 9002 is selected, this window allows selection of the following items to be
controlled by the contact buttons:
•
LOAD BANK
- assigns the button to select one of the 32 preset memories (SCENE
or EVENT**)
•
VOLUME UP
-Sets that button to control a volume up function
•
VOLUME DOWN
- Sets that button to control a volume down function
3.
If
LOAD BANK
is selected in # 2, then this
selects one of the 32 preset Scene
memories to be loaded.
4.
If a VOLUME or ZM-9002 controller is selected, then a box appears allowing selection of
an input or output channel to be controlled.
5.
If
Volume UP
or
DOWN
is selected for
ZM controller buttons in #2
, these set the
In/Out
channel
# to be controlled, as well as the dB increment for each button press.
33