TKH
TKH Security | Siqura EX PTZ Series |
Installation manual v4
5-66
Description
The EX PTZ unit is a variable speed stainless steel PTZ camera station specifically
designed for Hazardous Area applications. The design of the unit ensures the best
protection from external agents along with easy installation and maintenance service. EX
PTZ camera stations are equipped with the latest generation zoom module day/night and
thermal imaging cameras, but they are also available for customer-specified cameras.
The EX PTZ (D) camera stations have been designed and certified to the ATEX Directive
2014/34/EU, UKSI 2016:1107 (as amended by 2019:696) and to INMETRO to the
following:
II 2 G Ex db op pr IIC T6 Gb -
40°C ≤ Tamb ≤ +60°C
II 2 D Ex tb IIIC T85°C Db
-4
0°C ≤ Tamb ≤ +60°C
II 2 G Ex db op pr IIB T5 Gb -
40°C ≤ Tamb ≤ +75°C
II 2 D Ex tb IIIC T100°C Db -
40°C ≤ Tamb ≤ +75°C
The EX PTZ D-IR camera stations have been designed and certified to the ATEX Directive
2014/34/EU, UKSI 2016:1107 (as amended by 2019:696) and to INMETRO to the
following:
II 2 G Ex db op is op pr IIC T5 Gb
-
40°C ≤ Tamb ≤ +40°C
II 2 D Ex tb op is IIIC T100°C Db
-
40°C ≤ Tamb ≤ +40°C
II 2 G Ex db op is op pr IIB T4 Gb
-
40°C ≤ Tamb ≤ +60°C
II 2 D Ex tb op is IIIC T135°C Db
-
40°C ≤ Tamb ≤ +60°C
The surface temperature class of the device was determined only with ambient air
temperature, without taking into consideration direct sunlight. The IP rating of the unit is
IP66/IP67.
This product must only be installed by suitably trained personnel in accordance with the
relevant code of practice (e.g., EN60079-14). These instructions are intended for their sole
use.
CAUTION:
It is recommended to use proper certified cable glands and connection cables