TKH
TKH Security | Siqura EX PTZ Series |
Installation manual v4
19-66
Technical Data
Mechanical
Construction
AISI316L Stainless Steel
Finish
Electro-polished
Pan
Angle: 350° (+/- 175° or continuous rotation); Speed: up to
40°/second peak; Torque: 80 Nm
Tilt
Angle: 180° (+/- 90°); Speed: up to 20°/second peak; Torque:
107 Nm
Maximum load
25 kg
Cable entries
M25x1.5
Electrical
Thermostatically
controlled heater
T[°C] ON = 12 ± 4 °C, T[°C] OFF = 20 ± 3 °C
Supply voltage
24 V~ 50/60 Hz, 115 V~ 50/60 Hz, 230 V~ 50/60 Hz
Power consumption
95 W Max (120 W Max for EX PTZ D)
Certifications EX PTZ and EX PTZ D
Weatherproof standard
IP66/IP67
Rating
II 2 G Ex db op pr IIC T6 Gb -
40°C ≤ Tamb ≤ +60°C
II 2 D Ex tb IIIC T85°C Db -
40°C ≤ Tamb ≤ +60°C
II 2 G Ex db op pr IIB T5 Gb -
40°C ≤ Tamb ≤ +75°C
II 2 D Ex tb IIIC T100°C Db -
40°C ≤ Tamb ≤75°C
ATEX Standards
EN 60079-0:2018; EN 60079-1:2014;
EN 60079-28:2015; EN 60079-31:2014
IECEx Standards
IEC 60079-0:2017; IEC 60079-1:2014-06;
IEC 60079-28:2015; IEC 60079-31:2013
INMETRO
ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-28; ABNT NBR IEC 60079-31
UKEX
UKSI 2016:1107 (as amended by UKSI 2019:696)
Schedule 3A, Part 2
Compliancy
CE, UKCA, INMETRO