TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura EX PTZ Series |
Installation manual v4
13-66
7. PTZ installation
This step describes the pan and tilt receiver which is integrated in the PTZ camera station
for RS-485 communication.
The 8-way dip switch
(DS1
) on the telemetry receiver
can be used to set up the unit address (binary). When
a switch is on the ON position, the relative digit has
value 1, otherwise the value is 0. Switch 1 is referred
to the least significant digit (2
0
), while switch 8 is
referred to the most significant digit (2
7
).
For example, the address 13 (00001101 in binary) can be set up turning ON the switch 1, 3
and 4 (see figure).
The default address is 1.
Default limits
The unit is set with default values to achieve the following angles: +/- 90° Pan (left/right);
+/- 90° Tilt (up/down). CR versions do not have default pan limits. Factory limits are about
+/- 175° Pan (left/right) and +/- 100° Tilt (up/down). CR versions do not have factory pan
limits.
Change the default limits
Warning:
Setting the Pan limits (set 80 and 81) will delete all the pan saved presets.
Pan and tilt receiver
Left Limit
Preset
Set 70
Clear
limit
Preset
Set 80
Set
limit
Right Limit
Preset
Set 71
Clear
limit
Preset
Set 81
Set
limit
Up Limit
Preset
Set 72
Clear
limit
Preset
Set 82
Set
limit
Down Limit
Preset
Set 73
Clear
limit
Preset
Set 83
Set
limit