5 Cable routing and installation
5.1 Cable feed from the operator
The C-rails allows the use of ACE Tube clips for fixation of
cable protection tubes or cable. It is recommended to use
them.
Note: Tube clips are not included in the shipment, they
must be separate ordered as accessory item.
For example click the Tube clips into the profile rails. Take
the accessories kit from the shipment and seal at both ends
with the 4 round foam the rails.
The feeder cable of the operator (e.g. 48 fibers in 4 buffer
tubes) is inserted at the top position in the tube clip at the
rails and routed through the foam sealing via the upper
radius limiter into the base to the lateral cable clamp.
Select the center of the strain relief positions on the cable
sheath. Likewise, mark as well the stripping position of the
cable sheath approx. 2cm below the clamp position of the
cable tie wrap.
Foam adhesive tape is applied to the center markings of the
strain relief around the cable sheath.
Remove the cable sheath, in accordance to instruction of
the cable manufacturer over a length of approx. 4m. Then
fix the cable with cable ties at the clamp and fix, if applicable
the central cable strength member at the intended position
at the clamping plates.
Combine the individual loose tubes into one strand.