8
© Titan Tool Inc. All rights reserved.
cleanup
Special cleanup instructions for use with
flammable solvents:
• Always flush spray gun preferably outside and at least one
hose length from spray pump.
• If collecting flushed solvents in a one gallon metal
container, place it into an empty five gallon container, then
flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
IMPORTaNT: The sprayer, hose, and gun should be cleaned
thoroughly after daily use. Failure to do so permits material
to build up, seriously affecting the performance of the unit.
always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a fire
or explosion in the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
2. Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent (refer to recommendations of the material
manufacturer). An example of the appropriate solvent is
water for latex paint.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve to its PRIME position.
NOTE: hold the return hose in the waste container when
moving the PRIME/SPRay valve to PRIME in case
the sprayer is pressurized.
6. Move the engine ON/OFF switch to the ON position and
start the engine.
Pressure
Control
Knob
Sprayer
ON/OFF
Switch
Sprayer
ON/OFF
Switch
7. Turn on the sprayer by moving
the sprayer ON/OFF switch to
the ON position.
8. Slowly turn the pressure
control knob clockwise to
increase the pressure until
fluid starts to come out of the
return hose.
9. Allow the solvent to circulate
through the sprayer and
flush the paint out of the return hose into the metal waste
container.
10. Turn the pressure control knob fully counterclockwise to
its lowest setting.
11. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.
12. Move the PRIME/SPRAY valve to its SPRAY position.
13. Turn on the sprayer.
14. Turn the pressure control knob slowly clockwise to
increase pressure.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
15. Trigger the gun into the metal waste container until the
paint is flushed out of the hose and solvent is coming out
of the gun.
16. Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
NOTE: For long-term or cold weather storage, pump
mineral sprits through the entire system.
17. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
18. Store the sprayer in a clean, dry area.
IMPORTaNT: Do not store the unit under pressure.
cleaning the Spray Tip
1. Flush the gun with solvent immediately after the work is
completed.
2. Oil the sliding pins to prevent them from seizing up.
Should the spray tip become clogged, reverse
the spray tip with the lever and pull the trigger.
Once the obstruction comes out of the spray tip,
release the trigger, reverse the spray tip back to
the spray pattern setting, and resume spraying.
Do not attempt to clean the tip with your finger.
Do not use a needle or other sharp pointed
instrument to clean the tip. The hard tungsten
carbide is brittle and can be chipped.
Maintenance
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts, or electric shock.
NOTE: all honda engine work should be performed by
a honda authorized service center.
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips screwdriver
3/8” hex wrench
needle-nose pliers
5/16” hex wrench
adjustable wrench
1/4” hex wrench
rubber mallet
3/16” hex wrench
flat-blade screwdriver
1/8” hex wrench
1/2” open-end wrench
7/8” open-end wrench
1. Before repairing any part of the sprayer, read the
instructions carefully, including all warnings.
IMPORTaNT: Never pull on a wire to disconnect it. Pulling
on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer
to be sure that the problem is corrected. If the sprayer
does not operate properly, review the repair procedure to
determine if everything was done correctly. Refer to the
Troubleshooting section to help identify other possible
problems.
3. Make certain that the service area is well ventilated in
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
4. If you have any further questions concerning your TITAN
airless sprayer, call TITAN
:
Technical Service (U.S.)
.......................
1-800-526-5362
Fax ................................................
1-800-528-4826