26
Compact Ventilation Unit
6.2 Placement guidelines
The device is most useful in rooms where people spend most of their time, i.e. those
most affected by breathing: bedrooms, children’s rooms, living rooms, etc.
Select the location of the unit taking into account its dimensions (height 514 × width
454 × depth 163 mm) and power cord length (4.5 m). At least 50 mm clearance from
the floor, walls and ceiling must be provided. The distance between the window jamb
and central point of the opening in the outer wall must be at least 500 mm. The device
may be positioned at any height, even below the ceiling, since it can be controlled by a
remote control unit. The composition of the wall behind it must allow for a ventilation
duct to be drilled. There must be no service lines (electric wiring, heating or water sup-
ply pipes, etc.) in the drilling area.
6.3 Installation
1. Make sure that the device will be freely accessible in the planned location and
there is enough space in front of the maintenance panel to perform maintenance.
2. Follow the detailed installation guidelines on the mounting template.
3. The factory warranty covers only devices mounted by the Manufacturer’s certi-
fied installation experts.
4. Please pay careful attention to the correct installation of the device, which is cru-
cial for ensuring both its proper operation and for the warranty obligations. Make
sure that the installation expert fills in all necessary installation information on
the Service Ticket.
6.4 Electric wiring
Before operation, the device must be connected to the electrical mains supply.
Power parameters: AC 230 V, 50 Hz, single-phase, with protective grounding. The
power capability of the line must be at least 2 kW.
After connection to the mains supply, turn on the power switch on the right panel.
The device then goes into standby mode (section 5.3.5).
7. MAINTENANCE
Maintenance of the device consists in scheduled replacement of filters in accor-
dance with their natural wear.
The base filter is to be replaced yearly, provided that the surface of the base filter is
regularly cleaned, as necessary. To clean the base filter, a household vacuum cleaner
may be used. If regular base filter cleaning cannot be provided, it should be replaced
once every 6 months, depending on the operating conditions.
Please note! Do not use any detergents for filter cleaning, do not wash or flush with
water. Make sure not to damage the filtering surface when cleaning.
The high-efficiency E11 (H11) HEPA filter must be replaced at least once a year.