15
be switched off completely: press simultaneously and hold for 2 s the buttons [SET], [-]
and [+] on the control panel (not available for RC operation).
Sound signals are inactive when the device is in automatic mode (section 5.4).
Type
Value
1 signal
«Command recognized», «Function enabled»
2 signals
«Function disabled»
4 signals
«Filter lifetime timer renewed»
5.3.5 Standby mode
When the device is turned off using the RC, the key on the control panel or via
the MagicAir system, it enters the Standby mode (Fig. 11, 12). In the standby mode
the device does not perform its operating functions (the flap is closed, the fan is off),
but the power is still connected and the control circuitry is enabled. The standby mode
indication is displayed on the LCD screen as flashing dashes (marked as dashed lines
in the Figures below):
Blinking dashes
Figure 11. Standby Mode Indication
Blinking dashes
Figure 12. Standby mode as indicated on the LCD display, if timer is on
Switching between Standby and active modes is performed by one of the following
actions:
•
pressing the button on the device control panel,