The F7 base filter traps coarse and medium size dust particles, lint, soot and aller-
gens with efficiency up to 90%. It extends the service life of the high-efficiency HEPA
filter E11(H11).
If necessary, the intake air can be heated to the required temperature.
The high-efficiency HEPA filter E11 (H11) entraps the finest particles of dust, aller-
gens, bacteria, viruses and mold spores with efficiency above 95%. The E11 filtration
grade is the air cleaning standard for medical facilities. Only E11 grade filters can en-
trap hazardous microorganisms (lower class filters cannot stop them).
The adsorption catalytic filter AK deep-cleans the air, removing the major compo-
nents of exhaust fumes, industrial emissions, odors and smoke.
The cleaned air at comfortable temperature is fed into the room by a fan.
The high-efficiency E11 (H11) HEPA filter can be replaced with an absorption cat-
alytic АK-XXL filter with enhanced performance. After the АK-XXL filter is installed the
device will clean the air from harmful substances in concentrations even as high as 10
times above maximal permissible levels. Strong unpleasant odors are removed as well.
The dust filtration performance remains at 80-90% level.
5.3. Control and Indication
The user interface of the device consists of the following elements:
•
Liquid crystal display (LCD display),
•
Control panel buttons,
•
Remote control (RC),
•
Sound warnings.
These elements help control the parameters of the device and adjust its settings
as required.
If the device is coupled with a MagicAir system (section 5.4), the device is then con-
trolled automatically. Switching between automatic and manual control can be done
in one of the following ways:
- double-pressing any button on the control panel or remote control,
- pressing and holding any button on the control panel.
5.3.1 LCD display
All relevant information with current device settings is indicated on the LCD display.
The LCD backlighting turns on immediately after any button is pressed on the control
panel or remote control (with the exception of when the device is turned off using the
button ) and automatically turns off after 10 s. If the device is under automated con-
trol of the MagicAir system, the backlighting is disabled.
LCD messages are explained below